Troubleshooting (cont.)
Symptoms
Cause
C. Poorly adjusted
2.
Running fill
A. Water level is
valve.
B. Flush valve
C. Flush valve is
4.
Carrier and bowl
A. Insufficient
flex when used.
5.
No water flow.
A. Supply stop
1247365-2-B
Recommended Action
C. Check the threaded
rod.
rods behind the face
plate to make sure
that they are threaded
out far enough to
make contact with the
flush buttons. If they
are not, thread the
rods out to the correct
length and tighten
down the nuts to lock
the rods in place.
A. Lower the water level
too high.
in the tank by turning
the knob at the top of
the threaded rod
counterclockwise until
the fill valve shuts off
when the water level
reaches the marked
waterline in the tank.
B. Replace gasket or
gasket or flush
flush valve as
valve are
necessary.
damaged.
C. Check flush valve and
sticking open.
actuating mechanisms
for free movement.
Push button actuators
should raise levers
then spring back
without force. Replace
components as
necessary.
A. Add additional
support for
support members, and
frame.
mount the frame with
1/4" or larger lag
screws.
A. Open the supply stop
located in tank
(located on the left
is closed.
side).
18
Kohler Co.