114C IM 14Aug06
succession from the largest to the smallest as
shown in illustration 10. When the stud edge is
detected, the "stud" indicator and vertical "EDGE"
symbol will appear as shown in illustration 11.
The unit will also sound a constant tone.
2. Use the indicator line to mark the stud edge.
3. Continue sliding past the stud until the indicator
turns off and the unit stops beeping.
4. Repeat steps 1 and 2 in the other direction.
5. The midpoint between the two marks is the stud
center.
ILLUSTRATION 10
Mark1
Side
Direction
Steps 1 & 2
8/14/06
7:40 PM
ILLUSTRATION 11
Stud Being Detected
Mark2
Side
Direction
Steps 3 & 4
ILLUSTRATION 12
–9–
Page 10
Stud
Center Mark
Steps 5