V300
The V300 can be adapted to a two-residence format with a multi-button station. However, this type of installation requires the
addition of a junction box (not supplied in the kit) to be placed between the door station and the monitors in each (see diagram
below).
The monitors are installed as per the standard installation (see "4.1 Installation for one residence") with a maximum distance of 100
m between the door station and the monitor furthest away. Before installing the monitors, the switch (18) at the rear of the monitors
must be configured to distinguish between the two residences and thus be able to use the two call buttons on the door station:
6-1
6-2
6-1
Call button for residence 1
6-2
Call button for residence 2
Avoid installing the camera facing a light source, as images of visitors may be impaired.
We recommend that a silicon seal be applied between the rain shield and the wall/pillar (but not on the lower section of the rain
shield) and that the door station be fitted at a height of approximately 1.60 m.

5.1 Wiring the door station

[1]. Identify the mounting points with the rain shield.
Drill and fit plugs suitable for your wall/pillar.
Route all the cables into the rain shield.
[2]. Fix the rain shield to the wall/pillar.
Copyright © 2018 SOMFY ACTIVITES SA. All rights reserved.

5 INSTALLING THE DOOR STATION

Residence 1
18
Residence 2
18