Datos técnicos
8.5 Datos técnicos de X-300EEC
Tabla 8-41
Solicitación respetada / categoría
(norma)
Vibration
(IEC 60068-2-6)
Vibration
(IEEE1613 Class V.S.2)
Schock
(IEC 60068-2-27)
182
Estabilidad mecánica
Condiciones de comprobación
Frequency range 10 Hz to 150 Hz:
● Transit frequency: 58 Hz to 60 Hz
● Peak value of the displacement [mm] below the transit
frequency: 0,075
● Peak value of the acceleration [g] above the transit
frequency: 1
● Number of cycles per axis: 20
Frequency range 5 Hz to 150 Hz:
● Transit frequency: 8,4 Hz
● Peak value of the displacement [mm] below the transit
frequency: 3,5
● Peak value of the acceleration [g] above the transit
frequency: 1
● Number of cycles per axis: 10
● Octaves / min: 1
Frequency range 2 Hz to 100 Hz:
● Frequency range: 2 Hz to 100 Hz
● Transit frequency: 13,2 Hz
● Peak value of the displacement [mm] below the transit
frequency:1
● Peak value of the acceleration [g] above the transit
frequency: 0,7
● Number of cycles per
● Velocity: <10 mm/s
● Frequency: 1...150 Hz
● Acceleration: 15 g
● Duration of the pulse: 11 ms
● Number of shocks per direction: 3