7.
Turn the clamping cams clockwise so that the camlock studs are
clamped.
8.
Check radial and axial run-out on the check collar of the chuck and align
if necessary.
Flange mounted.
5.2.3 Flange Pursuant to DIN-ISO702-3 with Camlock Studs
1.
Clean the mating surfaces of the collet chuck CAPTIS-M and of the
flange.
2.
Place the flange with the external fit on the collet chuck CAPTIS-M and
firmly tighten with the fixing screws. For tightening torque, see Chapter
3.2 Technical Specifications, page 62.
122017 / 1.0
Flange pursuant to DIN-ISO702-3 with camlock studs, see
Chapter 5.4 Optional Accessory, page 76.
Assembly