Sime RMG MK.II Serie Manual De Instalación página 41

Ocultar thumbs Ver también para RMG MK.II Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLER INSTRUCTIONS
CONTENTS
1
DESCRIPTION OF THE BOILER. . ...........................................................................................................pag.....42
2
INSTALLATION. . ....................................................................................................................................pag.....43
3
CHARACTERISTICS. . .............................................................................................................................pag.....47
4
USE AND MAINTENANCE.....................................................................................................................pag.....49
Our. Company. declares. that. RMG. MkII. boilers. comply. with. the. essential. requirements. of. the. following.
directives:
-.Boiler.Efficiency.Directive.92/42/EEC
-.Gas.Appliances.Directive.2009/142/EC
-.Electromagnetic.Compatibility.Directive.2014/30/UE
-.Low.Voltage.Directive.2014/35/UE
When. carrying. out. commissioning. of. the. boiler,. you. are. highly. recommended. to. perform. the. following.
checks:
-. Make.sure.that.there.are.no.liquids.or.inflammable.materials.in.the.immediate.vicinity.of.the.boiler.
-. Make.sure.that.the.electrical.connections.have.been.made.correctly.and.that.the.earth.wire.is.connected.
to.a.good.earthing.system.
-. Open.the.gas.tap.and.check.the.soundness.of.the.connections,.including.that.of.the.burner.
-. Make.sure.that.the.boiler.is.set.for.operation.for.the.type.of.gas.supplied.
-. Check.that.the.flue.pipe.for.the.outlet.of.the.products.of.the.combustion.is.unobstructed.
-. Make.sure.that.any.shutoff.valves.are.open.
-. Make.sure.that.the.system.is.charged.with.water.and.is.thoroughly.vented.
-. Purge.the.system,.bleeding.off.the.air.present.in.the.gas.pipe.by.operating.the.pressure.relief.valve.on.
the.gas.valve.inlet.
CHARACTERISTICS OF THE SYSTEM SAFETY VALVE: calibration pressure: 4 bar; maximum generator power: 205.8 Kw,
1/2" x 3/4" fixtures (see Caleffi catalogue, code 527440).
CONFORMITY
IMPORTANT

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido