TROUBLESHOOTING

Sudden Starts. If power is on to pump
when thermal overload resets, pump may start without
warning. If you are working on pump, you may get an
SYMPTOM
A. Pump fails to operate:
B. Pump fails to empty sump:
C. Pump will not shut off:
Limited Warranty
F.E. MYERS warrants to the original consumer purchaser ("Purchaser" or "You") of the products listed below, that they will be free from defects
in material and workmanship for the Warranty Period shown below.
Product
Jet pumps, small centrifugal pumps, submersible pumps and
related accessories
Fibrewound Tanks
Steel Pressure Tanks
Sump/Sewage/Effluent Products
Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper installation, or
improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will
void the warranty. Note also that three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of
the recommended size or the warranty is void.
Your only remedy, and F.E. MYERS's only duty, is that F.E. MYERS repair or replace defective products (at F.E. MYERS's choice). You must
pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon
as a problem is discovered. No request for service will be accepted if received after the Warranty Period has expired. This warranty is not
transferable.
F.E. MYERS SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES,
INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE
FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied
warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other
rights which vary from state to state.
This Limited Warranty is effective June 1, 2011 and replaces all undated warranties and warranties dated before June 1, 2011.
In Canada: P. O. Box 9138, 269 Trillium Dr., Kitchener, Ontario N2G 4W5
CORRECTIVE ACTION
1. Check to be sure that power cord is securely plugged into outlet or securely wired
into controller or switch box. Disconnect power to outlet before handling pump
or motor.
2. Check to be sure you have electrical power.
3. Check that liquid fluid level is high enough to activate switch or controller.
4. Check to be sure that 5 mm (3/16") vent hole in discharge pipe is not plugged.
5. Check for blockage in pump inlet, impeller, check valve or discharge pipe.
6. Thermal overload may have tripped. Test start pump; if it starts and then stops
immediately, disconnect from power source for 30 minutes to allow motor to cool,
then reconnect to power source. Check for cause of overheating/overloading.
1. Be sure all valves in discharge piping are fully open.
2. Clean out discharge pipe and check valve.
3. Check for blockage in pump inlet or impeller.
4. Pump not sized properly. A higher capacity pump may be required.
1. Check switch or controller automatic floats for proper operation and location.
See installation instructions for switch/controller.
2. If pump is completely inoperative or continues to malfunction, consult your
local serviceman.
F.E. MYERS
293 Wright Street, Delavan, WI 53115
Phone: 888-987-8677 • Fax: 800-426-9446 • www.femyers.com
Phone: 519-748-5470 • Fax: 888-606-5484
electrical shock or impeller may catch fingers or tools.
Disconnect power before servicing pump.
Warranty Period
whichever occurs first:
12 months from date of original installation,
or 18 months from date of manufacture
5 years from date of original installation
5 years from date of original installation
12 months from date of original installation,
or 24 months from date of manufacture