Package Contents; Installation Overview - STEINEL FL300W Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2
• Turn power off at the circuit breaker before installing the sensor
• Sensor must be installed and used in accordance with appropriate electrical codes and
regulations
• Installation by a qualified electrician is recommended

Package Contents

FL300 outdoor sensor with
dual lampholders
One crossbar
Two washers
Two nuts
One 3" chase nipple
Four mounting screws

Installation Overview

Needed for installation
Exterior wall mount installation:
• Weatherproof double-gang junction
box with gasket (mounting screw holes
are 5.25" apart)
Exterior wall mount installation without
double-gang box:
• Crossbar (included)
• Weatherproof silicone caulk
Soffit mounting:
• Weatherproof junction box
• 1/2" threaded coverplate with foam
gasket and coverplate screws
www.steinel.net
(800) 852-4343
WARNING
Applications
• Exterior: entryways, carports,
balconies, patios
Intended uses
• Outdoor lighting
• NOT suitable for alarm systems
Environmental considerations
• Weather can affect operation of the
sensor. Strong gusts of wind, snow,
rain and hail can cause switching
errors since the sudden temperature
changes cannot be distinguished from
heat sources.
Two 1/2" Phillips screws
Two shrouds
Two wire nuts
One standard backplate (wall
mounting)
One solid backplate (soffit
mounting)