STEINEL FL300W Instrucciones De Instalación página 6

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6
Wiring
When installing, make sure power has
been switched off at the breaker and
check that the circuit is dead with a
voltage tester.
The leads consist of two wires:
L = hot wire (black)
N = neutral wire (white)
If in doubt, identify the individual
conductors with a voltage tester or
contact a qualified electrician.
Operation
The FL300 operates by turning lights
on automatically when occupancy is
detected and off when the space is left
vacant.
Light level function
The light level feature keeps lighting
off during daylight hours, regardless of
occupancy.
Manual override
Adding a wall switch provides a manual
override function. While the switch is ON,
the sensor is in occupancy control mode.
Users can turn the switch OFF at any time
to keep lights OFF.
The switch can be used to override lights
ON for 4 hours. To do this, the switch
must be in the ON position and the sensor
has gone through warm up. Toggle switch
OFF ON OFF ON within 2 seconds. Lights
will now remain on for 4 hours. To verify
that the sensor is in manual override, you
should see a red indicator light behind the
lens in the upper right hand corner.
www.steinel.net
(800) 852-4343
NEUTRAL
Neutral
HOT
Hot
Local OFF
Local OFF
Switch (optional)
Switch (optional)
To resume sensor mode prior to the 4
hours, simply flip the switch OFF ON
once within two seconds. Lights will
turn off and the sensor returns to sensor
mode.
Surge protection
Every sensor contains built in surge
protection. This feature will reset the
unit automatically after power surges,
power outages, and power shortages.
Surge protection protects the sensor if it
is miswired as well. If miswired, shut off
power, correct the wiring, and the sensor
will then operate correctly.
Line (Black)
LINE (BLACK)
Neutral (White)
NEUTRAL (WHITE)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fl300b

Tabla de contenido