Mounting
Placement guidelines
• Unique dual mounting system enables
the FL300 to mount either to a wall or
ceiling under a building soffit.
• Detection lens must have a clear,
unobstructed view of detection area.
Soffit mounting
Materials needed (included):
- One solid backplate
- One threaded 3" chase nipple
- Two 1/2" Phillips screws
Materials needed (purchase separately):
- One weatherproof junction box
- One 1/2" threaded coverplate with foam
gasket and coverplate screws
www.steinel.net
Weatherproof 1/2"
threaded coverplate
Threaded 3" chase
nipple
Opening where plug
is removed and chase
nipple snaps in
(800) 852-4343
• Ideal mounting height is 8-12 feet.
• If needed, apply silicone sealant
around the junction box to ensure
weathertight installation.
• Remove sensor's backplate and
remove plug on top of the unit by
pushing up on plug from inside of unit.
• Run connection wires from sensor
through threaded 3" chase nipple,
cover and gasket. Make sure wires
extend through junction box cover and
gasket (see illustration).
• Fasten the solid backplate to sensor
using two Phillips screws.
• Connect wires from sensor to
corresponding wires in junction box
(see Wiring).
• Align gasket and coverplate with
junction box and secure with
coverplate screws.
• Connect threaded 3" chase nipple to
coverplate by threading it into the 1/2"
knockout.
• Press sensor housing into the threaded
3" chase nipple making sure the
sensor lens is facing the coverage area
and its field of view is not obstructed.
You have a firm connection when it
snaps into place.