TECHNICAL DETAILS

Operating voltage:
Current:
Relays:
Operating temperature:
Bolt throw:
Backset:
Forend:
Spindle:
Connection cable:
Adjustable delay:
Door clearance:
Settable functions:
Monitoring outputs:
Strike plate:
!
The use of a universal building key is prohibited because it can seriosly damage the lock.
TESTED ACCORDING TO THE STANDARDS
EN 179
EN 1125
EN 1634-1
EN 61000-6-1:2007
EN 61000-6-3:2007
12 - 24 V DC (± 15%)
12 - 18 V AC (-10% / +15%), RMS
12 V DC
80 mA Idle
450 mA normal driver
1300 mA max.
24 V DC
40 mA Idle
220 mA normal driver
600 mA max.
Max. 0.8 A 30 V AC/DC resist. 20 W
-20°C - +60°C
20 mm (deadbolt), 10 mm (double action bolt)
55, 60, 65, 80, 100 mm (EL520, EL522)
30, 35, 40, 45 mm (EL420, EL422)
20, 24 mm (EL520, EL522)
24, 28 mm (EL420, EL422)
9 mm (8 mm with snap spindle adapter)
EA218 (6 m) / EA219 (10 m) 18 x 0.14 mm2
2 - 15 s
2 - 5.5 mm (between forend and strike plate)
Mechanical functions:
- Opening direction of trigger bolt
Bolt deadlocked
Lock open
Trigger bolt in
Handle used
Cylinder used
Sabotage
EA321, EA322, EA323, EA324, EA325, EA326, EA327, EA328,
EA329, EA330, EA331, EA332
3 7 6 1 1 3 2 2 A
Exit
3 7 6 1 1 3 2 1/2 A Panic exit
Fire
EMC
EMC
R