Troubleshooting

Problem
No function when Throttle Trigger (11)
is operated. Oscillating Spindle (21)
rotates freely
Drive Pulley (12) performance is
restricted, yet air flows freely from the tool
Seized Drive Pulley (12)
Sander will not turn off when Throttle
Trigger (11) is released
8
Possible Cause
Air supply issue
Defective Throttle Trigger or throttle components
Internal vane seized
Broken internal vane
Defective internal Throttle Trigger components
Solution
Check all connections between compressor and tool, and ensure the operating pressure
is set correctly
In the event the internal throttle mechanism becomes jammed. Check for dirt within the
Air Inlet (9) and remove. Pour a small amount of air tool oil (not included) into the Air
Inlet, reconnect the air supply and operate the Throttle Trigger in small bursts. If the tool
still ceases to function, return to an authorised Silverline service centre
Disconnect the air supply. Pour a small amount of air tool oil (not included) into the
Air Inlet (9), reconnect the air supply and operate the Throttle Trigger in small bursts.
Periodically tap the Drive Pulley using a rubber mallet (not included). If the tool still ceases
to function, return to an authorised Silverline service centre
Return to an authorised Silverline service centre
Return to an authorised Silverline service centre