10. Technical data

Main features
Rated power
Active power
Technology
IN/OUT Configuration
Neutral system
Bypass
Overvoltage category
Input electrical characteristics
Rated input voltage
Range of input voltages
Input frequency
Max input current
(with minimum input voltage
and battery charger active)
Power factor on input
Total harmonic distortion of the input current
Inrush current
Icp Presumed short circuit current
Electrical output characteristics (normal mode)
Rated output voltage
Rated output frequency
Tolerance on the output frequency
Max output current
Crest factor admitted on the output current
Total harmonic distortion of output voltage
on linear rated load
Total harmonic distortion of output voltage
on non-linear rated load
Network efficiency (online mode)
Efficiency in ECO MODE
Overload admitted
3 101 66
3 101 67
3000 VA
4000 VA
3000 W
4000 W
on-line, double conversion, Classification according to EN62040-3:
VFI-SS-111
Single-phase / Single-phase
Neutral passing straight from input to output (not isolated)
Automatic (static)
Manual (for maintenance - optional)
OVC II
3 101 66
3 101 67
184 V – 264 V with rated load
50 / 60 Hz ± 2% (autosensing)
50 / 60 Hz ± 14% (by software configuration)
18 A
24 A
PF > 0,99
THDi < 3% (full load)
100% of the rated current
3 101 66
3 101 67
230 V ± 1%
50 / 60 Hz
synchronised with the input (with a range of ± 2% to ± 14%,
selected through the software)
± 1% when not synchronised
13 A
17,3 A
< 0,5%
up to 96%
99% max
(by software configuration)
125% for 10 minutes without automatic bypass activation
150% for 60 seconds without automatic bypass activation
WHAD HE 3-4-5-6 kVA
3 101 68
3 101 69
5000 VA
6000 VA
5000 W
6000 W
3 101 68
3 101 69
230 V
30 A
35 A
10 kA
3 101 68
3 101 69
21,7 A
26 A
3:1
< 3%
39