In Setting(s) press Check the impedance of the zone... to open impedance menu. Select detection 
mode,  in  Normal  mode  lines  are  checked  continuously  whenever  music  is  not  activated.  In  other 
modes lines are checked at selected intervals, cutting the music (0.5 seconds).  
Then, select the Error range, the difference between initial and current measurement required to 
indicate fail, It can be 5‐30%, and Finally press 
is done values are stored automatically. 
 
IMPORTANT  NOTE:  24V  attenuators  and  speaker  line  surveillance  cannot  be  used  at  the  same 
time.  Attenuators  are  not  bypassed  neither  during  impedance  calibration  nor  during 
measurement. Please disable the speaker line surveillance for any zone with attenuators. 
5.7. SYSTEM STATUS 
State and Control menu is used to monitor system status. Once software is connected to NOVA‐500 
all system parameters are synchronized.  
5.7.1. Main panel 
NOVA Version 1.0
NOVA
to initiate measurement. After measurement 
NOVA‐500 connection status. 
Device without / with failures.
Voice Evacuation System
Page 28 of 34