1 - DESCRIPTION
is an environment controller equipped with 22 control outputs built-in. It monitors environment temperature, humidity and
Humitech Super
differential pressure in order to control a wide range of equipment, such as water spraying, cooling, heating, minimum ventilation, exhauster and
curtain devices.
2 - APPLICATION
It is designed to be used together with evaporation cooling systems for thermal comfort in agricultural facilities, incubators, aviaries and swine
housing.
3 - TECHNICAL SPECIFICATIONS
- Power Supply:
90 ~ 264 Vac (50/60Hz)
- Control Temperature:
-50 to 105 °C / -58 to 221 °F (resolution: 0.1 °C / 1 °F)
- Control Humidity:
0 to 100% RU (resolution: 0.1% RH)
- Control Pressure:
-200 to 200 Pa (resolution: 1 Pa)
- Commands: Alarms:
2 NC relays
Control Outputs: 19 NO relays and 1 NO-NC relay
(max. 300 mAper relay).
- Dimensions (W x H x D):
220 x 134 x 54 mm
- Operating Temperature:
0 to 40 °C
- Operating Humidity:
10 to 90% RH (without condensation)
4 - OUTPUT DESCRIPTION
MIN VENT 1 -
Minimum Ventilation 1
EXHAUS 1 (MIN VENT 2) -
EXHAUS 2 (MIN VENT 3) -
EXHAUS 3 (MIN VENT 4) -
EXHAUS 4 to EXHAUS 10 -
COOL 1 -
Cooling System 1
WAT SPRAY 1 -
Water Spray System 1
WAT SPRAY 2 -
Water Spray System 2
HEAT 1 -
Heating System 1
HEAT 2 -
Heating System 2
HEAT 3 -
Heating System 3
CURT -
Raise Curtain
CURT -
Lower Curtain
CURT RELEAS -
Curtain Release Relay (NO/NC)
NC ALARM 1 -
Alarm 1
NC ALARM 2 -
Alarm 2
5 - SERVICE PARAMETERS (ADVANCED SETTINGS)
operation settings (among others) can be configured for device outputs in the advanced settings menu. To enter the advanced
Humitech Super
settings menu hold
and
pressed for 2 seconds until theAccess Code selection is displayed. Press
. Value setting is selected through the
01-Code
Access Code
02-Min. Ventilat
Minimum Ventilation Parameters
03 Exhaust
-
Exhauster Parameters
04 Heating
-
Heating Parameters
05 Cooling
-
Cooling Parameters
06-Fogger
Water Sprayer Parameters
07 Curtain
-
Curtain Parameters
Press
to enter the selected function settings. The current value starts to blink when the parameter setting is configurable. The function value can
be changed by using
and
Function
Offset Temp 1
Description
C01@ 10.0 #
Function Code
Exhauster 1 or Minimum Ventilation 2
Exhauster 2 or Minimum Ventilation 3
Exhauster 3 or Minimum Ventilation 4
Exhauster 4 to 10
and
keys. Press
keys. Press
once again to set the new value or press
Function Value
Function Unit
to confirm the operation or press
08 Alarms
-
09 Datalogger
-
10 Program
-
11 Config
-
12 Clock
-
adjust
13-Name adjust
to cancel it and return.
26
to enter your selection. To go back, press
to cancel it.Available selections are:
Alarm Parameters
Datalogger Parameters
Daily Setpoint Programming
General Configuration Parameters
Date &Time Setting
Controller Name Setting