N04 - Differential to Turn Off Water Sprayer 2
Temperature difference to turn off Water Sprayer 2.
N05 - Humidity to Turn On Water Sprayer 1
When the relative air humidity is below this value the Water Sprayer 1 Output will be activated.
N06 - Humidity Differential to Turn Off Water Sprayer 1
Humidity difference to turn off Water Sprayer 1 Output.
N07 - Humidity to Turn On Water Sprayer 2
When the relative air humidity is below this level the Water Sprayer 2 Output will be activated.
N08 - Humidity Differential to Turn Off Water Sprayer 2
Humidity difference to turn off Water Sprayer 2 Output.
N09 - High Humidity to Force Water Sprayers 1 and 2 OFF
Maximum air humidity threshold for turning both water sprayer outputs OFF.
N10 - High Humidity Differential to Restart Water Sprayers
Maximum air humidity differential to allow reactivating the water sprayer outputs.
N11 - Water Sprayer Outputs ON Time
Time period in seconds Water Sprayer outputs will be ON. If set to "0" the outputs will be permanently ON.
N12 - Water Sprayer output OFF Time
Time period in seconds Water Sprayer outputs will be OFF.
5.7 - Curtain
Operation parameters related the curtain control outputs (
Fun
T01
T02
T03
T04
T05
T06
T07
T08
T09
T10
T11
T12
T13
T14
T15
T16
T17
T01 - Curtain Control by Pressure Sensor
Determines whether the differential pressure sensor will be used for controlling the curtain.
" " - Differential pressure sensor will not be used;
No
"
" - Differential pressure sensor will be used.
Yes
T02 - Motor step time
Time the engine will remain on and off in order to raise or lower the curtain, when controlled by differential sensor.
T03 - Desired Differential Pressure
It's the desired differential pressure (pressure difference between internal and external environment).
T04 - Differential Pressure Range Allowed
Determines maximum and minimum pressure range values above and below the desired setpoint.
T05 - Curtain Level VM1 (if T01=0)
Time that the motor will remain turned on and off to raise or drop the curtain in the operation of minimum 1 ventilation output.
T06 to T15 - Curtain Level of EXAUSxx
When the differential sensor is not used, each fan group controlling the curtain will descend respecting the time configured in this parameter.
On the other hand, when the fan group is deactivated, the curtain will rise respecting the same time. When any of the EXAUS1, EXAUS2 or EXAUS3
outputs be set as VENT MIN 2, VENT MIN 3 or VENT MIN 4 respectively, the time is not considered, and the curtain will not rise or drop during the
activation/deactivation of these minimum ventilations.
CURTAIN CURTAIN
Description
Curtain Control by Pressure Sensor
Motor step time (if T01 = 1)
Desired Differential Pressure (if T01 = 1)
Differential Pressure Range Allowed (if T01 = 1)
Curtain Level VM1 ( if T01 = 0)
Curtain Level of EXHAUS 1 (if T01 = 0)
Curtain Level of EXHAUS 2 (if T01 = 0)
Curtain Level of EXHAUS 3 (if T01 = 0)
Curtain Level of EXHAUS 4 (if T01 = 0)
Curtain Level of EXHAUS 5 (if T01 = 0)
Curtain Level of EXHAUS 6 (if T01 = 0)
Curtain Level of EXHAUS 7 (if T01 = 0)
Curtain Level of EXHAUS 8 (if T01 = 0)
Curtain Level of EXHAUS 9 (if T01 = 0)
Curtain Level of EXHAUS 10 (if T01 = 0)
Curtain Release Time
Time between curtain self-adjustments (if T01 = 0)
and
CURTAIN RELEASE
CELSIUS
FAHRENHEIT
Standard
-
No
Yes
No
No
sec.
0
999
10
0
-200
200
Pa
10
-200
0
20
Pa
5
0
sec.
0
999
10
0
0
999
sec.
10
0
0
999
sec.
10
0
sec.
0
999
10
0
sec.
0
999
10
0
0
999
sec.
10
0
0
999
sec.
10
0
sec.
0
999
10
0
sec.
0
999
10
0
0
999
sec.
10
0
sec.
0
999
10
0
sec.
0
999
10
0
1
24
hours
1
1
32
).
Standard
-
Yes
No
sec.
10
999
200
Pa
10
20
Pa
5
sec.
999
10
999
sec.
10
999
sec.
10
999
sec.
10
sec.
10
999
999
sec.
10
999
sec.
10
sec.
999
10
sec.
10
999
999
sec.
10
999
sec.
10
sec.
10
999
24
hours
1