Maintenance

• A correct use and good maintenance will lengthen the
useful life of the welder.
CAUTION
• Only Certified personnel shall carry out
repairs. We recommend visiting a
Authorized Service Center to repair the welder and
purchase supplies and accessories.
• Before carrying out any type of repairs, please cut please
the power supply.
• Check regularly that the input and output cables are
firmly connected and are not exposed. Any anomaly shall
be repaired immediately.
Storage
• In the event the welder is to be stored for long periods
of time, it shall be kept in a dry and well ventilated place
to prevent humidity, oxide or toxic gases enter the
machine.
The storage temperature can be from -13 °F and up to
131 °F, and the relative humidity shall not be over 90%.
Nozzle
• The nozzle (D) shall be clean and free of spills. The
accumulation of spills inside the nozzle can cause an
electric shock in the contact tip and can blow a fuse in
the printed circuit or can cause expensive repairs to the
machine. To keep the contact tip free of spills and to
learn how to remove and replace it.
• Apply anti-adherence ointment into the nozzle
before starting to weld.
Torch Cable (MIG)
• Protect the mechanical wear in the torch cable mount (B).
• To clean the covering set back the micro wire rewinding
the spool. Secure the micro wire to the spool and
disconnect the mount from the torch in the control panel.
• Clean the inner covering with compressed air,
administered from the mount and up to the torch. If the
covering is clogged, replace the torch.
Micro Wire Feed Mechanism
• Verify regularly the micro wire feed mechanism. the
cleansing of the notches from the feed rod (A) is
indispensable to get a good job. Clean the rods once a
week. especially the feed rod notch. Eliminate any dust
accumulation.
A
Contact Nozzle
• The contact nozzle (C) is a consumable
C
element and shall be replaced when the
orifice gets bigger or the shape is changed.
The contact nozzle shall be kept free of
D
spills to allow the gas to flow correctly.
Cleansing
CAUTION
Every time the dust is cleaned cut the
power supply.
• To remove the dust from the too, use dry compressed air
(use a compressor or a bellow) to remove the dust from
inside the machine.
• If there is grease adhered, clean with a piece of cloth.
• The machine shall be cleaned thoroughly once a year if in
good maintenance conditions and each three month if it
has too much dirt accumulated.
• Check regularly the input and output cables from the
welder to guarantee a good connection and prevent
exposure. This checkup shall be carried out once a month
when fixed and each time you need to remove them.
B