6.3 Recognising magnets

It is essential that the following procedure is observed to ensure
completely safe operation of the door.
The door must be in the intermediate position before the magnet
recognition procedure can be started.
Do not press the safety edge during the magnet recognition
procedure.
Carry out two whole cycles (opening then closing) using buttons
1
2
3
4
STOP
Prog
1
2
3
4
STOP
Prog
1
2
3
4
STOP
Prog
1
2
3
4
STOP
Prog
7 - CHECKING OPERATION OF THE
RECEIVER
At the end of installation, it must be checked that the limitation of
forces complies with appendix A of the standard EN 12 453.

7.1 Operation in sequential mode

STOP

7.2 Integrated lighting

The lamp comes on each time a command is sent to the receiver.
It goes out 2 minutes after the door stops.

7.3 Orange light

7.4 Cells

If the cells are blocked when the door is closed, it stops, then re-opens fully.
If the cells are blocked when the door is opened, the door continues its
movement.
8
and .
STOP
STOP

7.5 Safety edge

If the safety edge is activated when the door is closing, it stops then re-opens
partially.
If the safety edge is activated while the door is opening, it continues its
movement.

7.6 Alarm (optional)

The alarm is triggered for 2 minutes if the door is fully closed and raised
manually. No movement of the door is possible when the alarm is sounding.
When the alarm sounds, press a button on a remote control memorised in the
receiver to stop it.
The alarm can only be stopped with a memorised remote control.

8 - CONNECTING ADDITIONAL DEVICES

8.1 General wiring diagram

Stop
Safety Edge
M
Sec
L1
N
L2
1
2
3
4
5
6
7
8
R
Type of
Terminal
Connection
terminal
1
Earth
RDO CSI 50 or 60
motor
2
L1
3
Neutral
4
L2
5
Contact
Fall protection - NC
contact
6
Shared
7
Contact
Safety edge safety
input
8
12 Vdc
12 Vdc safety edge
power supply
9
0 Vdc
10
Contact
NO contact
11
Shared
12
24 Vdc
24V - 3.5 W orange
light output
13
0 Vdc
14
24 Vdc
TX cell 24 V power
supply
15
0 Vdc
16
24 Vdc
RX cell 24 V power
supply
17
0 Vdc
18
Shared
19
Contact
Cell safety input (NC)
20
Test output
Cell safety test output
22
433.42 MHz aerial
KeySwitch
Flash
24V dc
24V Cell
Sec Cell
Test
Sec
9
10
11
12
13
14
15
16
17
18
19
20
24 Vdc
24 Vdc
Aerial
Comments
Wired 8k2 resistive safety
edge (terminals 7 - 8)
Wired optical safety edge
(terminals 7 - 8 - 9)
Sequential control
Maximum 4 W bulb
Transmitting photoelectric
power supply
Receiving photoelectric
cell power supply
Do not connect an offset
aerial (incompatible)
Copyright © 2014 Somfy SAS. All rights reserved.