1.8 Risk prevention
Risk prevention - roller garage door motorisation for
residential use
> Risk zones: measures to be taken to eliminate risks.
Zone 3
Zone 4
RISK
ZONE 1
Risk
of
crushing
between the ground
and the lower edge of
the door during closing
ZONE 2*
Risk
of
crushing
between the casing
and door
ZONE 3*
Risk of cutting or
trapping between the
door slats in gaps of
between 8 mm and 25
mm
ZONE 4*
Risk
of
crushing
between the runners
and door
* For zones 2, 3 and 4, no protection is required if the door
has continuous control or if the danger zone is more than
2.5 m above ground or any other permanent access level.
Copyright © 2014 Somfy SAS. All rights reserved.
WARNING
Zone 2
Zone 1
SOLUTION
Obstacle
detection
using
detection
using
a
force
measurement - see Force
measurement paragraph)
For operation with automatic
closing, install photoelectric
cells (see installation manual)
and door
Eliminate all sticking points
and all sharp edges from the
surface of the door
Eliminate any sharp edges
from the runners
between the runners and the
door
> Force measurement
Take the mid-height measurement of
1
the garage door by positioning the
measuring tool perpendicular to the
1400N
panel which is closing.
F
d
The standard stipulates:
-
-
400N
standard are validated by Somfy
during initial type testing.
150N
25N
T
d
2 - DESCRIPTION OF THE ROLLIXO
RECEIVER

2.1 Area of application

The ROLLIXO receiver, linked to a Somfy RDO CSI motor and a Somfy safety
edge solution, is designed to drive a vertically opening roller garage door for
residential use with the following external dimensions:
- Height = 4 m maximum
- Width = 6 m maximum
Number of cycles per hour: 5 cycles/hour spread evenly throughout the hour

2.2 Description of the receiver

10
14
12
13
9
8
7
11
No.
Description
1
Integrated lighting bulb
2
Receiver cover
3
Receiver cover bolt
4
External programming interface
5
Internal programming interface
6
433.42 MHz aerial
7
Plug-in terminals
8
Cable clamp
9
Cable clamp bolt
10
Alarm bolt
11
Fall protection shunt
12
Safety fuse for motor and integrated lighting
13
Spare fuse
14
E14 - 15W max - 230V bulb
1
4
5
2
3
6
3

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido