Connecting DC-Latching Solenoids
!
!
100' max
!
!
6
(30 m)
EN
1. Attach the black leads from each solenoid to the single common
wire (black lead) coming from the NODE-BT. Secure all wire
connections with waterproof connectors.
2. Attach one red wire from each solenoid to the corresponding
station wire (red lead) from the NODE-BT. The station numbers
are identified underneath the red wires of the NODE-BT. Secure
all wire connections with waterproof connectors.
Solenoid operation:
Use only DC-latching solenoids (P/N 458200) operating between
9-11 volts. 24-volt AC solenoids will not operate with NODE-BT.
Wiring distance:
The maximum wire distance between the solenoid and the NODE-BT
is 100' (30 m) using 18 AWG (1 mm
DE
Anschluss der DC Impulsspulen
1. Schließen Sie die schwarzen Drähte jeder Spule an den
Masseleiter (schwarzer Draht) des NODE-BT an. Sichern Sie alle
Kabelverbindungen mit wasserdichten Verbindern.
2. Schließen Sie ein rotes Kabel jeder Spule an das
entsprechenden Stationskabel (roter Draht) des NODE-BT
an. Die Stationsnummern sind unter den roten Kabeln des
NODE-BT angegeben. Sichern Sie alle Kabelverbindungen mit
wasserdichten Verbindern.
Betrieb der Spulen:
Verwenden Sie nur über DC Impulsspulen (P/N 458200) mit 9-11
Volt. 24-Volt AC Spulen eignen sich nicht für den Betrieb des
NODE-BT.
Verdrahtungsabstand:
Der maximale Drahtabstand zwischen der Spule und dem NODE-
BT beträgt 30 m bei einer Drahtstärke von mindestens 1 mm
) minimum wire gauge.
2
.