OPERATING INSTRUCTIONS
Before First Start-up — Break-in Procedure
Complete this procedure before using compressor for the first time. Once completed, it is not necessary to
repeat.
1. Turn ON / OFF switch (
2. Open the tank drain valve.
3. Plug in power cord.
4. Turn ON / OFF switch (
5. Turn ON / OFF switch (
6. Unplug power cord.
7. Close drain valve.
The compressor is now ready for use.
Before Each Start-up — Operating Procedure
1. Turn regulator knob fully counter clockwise (to the left) to close air flow.
2. Connect air hose to outlet of regulator.
3. Turn ON / OFF Switch (
4. Plug in power cord.
5. Turn ON / OFF Switch (
pressure.
6. Attach tire chuck or tool to end of hose.
7. Adjust regulator to proper pressure for tool or tire. Operate tool per instructions.
As air is depleted from the tank by use of a tire chuck, tool, etc., the compressor will restart automatically
at its preset "cut-in" pressure. When a tool is being used continuously, the compressor will cycle on and off
automatically.
8. Turn switch to OFF position (
Outlet Pressure Gauge
1. This gauge shows at-a-glance, air pressure at outlet. Air pressure is measured in pounds per square inch
(psi).
2. Be sure this gauge reads ZERO before changing air tools or disconnecting hose from outlet.

Tank Pressure Gauge

Gauge shows pressure in tank indicating compressor is building pressure properly.
MOISTURE IN COMPRESSED AIR
Moisture in compressed air will form into droplets as it comes from an air compressor pump. When
humidity is high or when a compressor is in continuous use for an extended period of time, this moisture
will collect in the tank. When using a paint sprayer, this water will be carried from the tank through the
hose, and out of the gun as droplets mixed with the spray material.
IMPORTANT: This condensation will cause water spots in a paint job, especially when spraying other
than water based paints. A filter in the air line, located as near to the gun as possible, will help eliminate
this moisture.
8
) to OFF position (
).
) to ON position ( ) and run compressor for 30 minutes.
) to OFF position (
).
) to OFF position (
).
) to ON position ( ) and let compressor run until it reaches automatic shutoff
), unplug power cord and drain tank of air when finished using compressor.