8. Specifications
VE.Bus BMS
Input voltage range
Current draw, normal operation
Current draw, low cell voltage
Load Disconnect output
Charge Disconnect output
VE.Bus communication port
Operating temperature
Humidity
Protection grade
Material and colour
Weight kg
Dimensions (hxwxd) in mm
Standards: Safety
Emission
Immunity
Automotive Directive
Cyrix Li-ion ct
(see Cyrix Li-ion datasheet for more
information)
Continuous current
Connect voltage
Disconnect voltage
Start Assist
Cyrix Li-ion load
Cyrix Li-ion Charge
Continuous current
Connect voltage
Disconnect voltage
Charge not active detection
General
Over voltage disconnect
Over temperature disconnect
Current consumption when open
Current consumption when closed
Operating temperature range
Protection category
Weight kg (lbs)
Dimensions h x w x d in mm
(h x w x d in inches)
10
Normally high (output voltage ≈ supply voltage – 1V)
Normally high, (output voltage ≈ supply voltage – 1V)
GENERAL
Two RJ45 sockets to connect to all VE.Bus products
ENCLOSURE
STANDARDS
12/24-120
120A
From 13,7V to 13,9V and 27,4V to 27,8V
with intelligent trend detection
From 13,2V to 13,4V and 26,4V to 26,8V
with intelligent trend detection
Yes
(The Cyrix remains engaged during 15
seconds after the control input has been
pulled twice to battery minus.)
12/24-120
Please use a Battery Protect instead: much lower power consumption
12/24-120
120A
Engages when voltage on the charger side
exceeds 13,7V to 13,9V and 27,4V to 27,8V
with intelligent trend detection
From 13,2V to 13,4V and 26,4V to 26,8V
with intelligent trend detection
The Cyrix disengages every hour and remains open in case of low voltage on the charger side
12/24-120
16V / 32V
<220mA / < 110mA
9 – 70VDC
10mA (excluding Load Disconnect current)
2mA
Floating when load needs to be disconnected
Source current limit: 2A
Sink current: 0A
Floating when charger should be disconnected
Source current limit: 10mA
Sink current: 0A
-20 to +50°C
0 - 120°F
Max. 95% (non-condensing)
IP20
ABS, matt black
0,1
105 x 78 x 32
EN 60950
EN 61000-6-3, EN 55014-1
EN 61000-6-2, EN 61000-6-1, EN 55014-2
EN 50498
Engages when voltage on the charger side
exceeds 27,4V to 27,8V and 54,8V to 55,6V with
intelligent trend detection
From 26,4V to 26,8V and 52,8V to 53,6V
with intelligent trend detection
Yes
<4mA
-20 to +50°C
IP54
0,11 (0.24)
46 x 46 x 80
(1.8 x 1.8 x 3.2)
24/48-120
24/48-120
24/48-120
120A
24/48-120
32V / 64V
< 110mA / <60mA
24/48-120