Step 5, Connect Ductwork; Step 6, Connect Electrical - Monogram ZV750 Instrucciones De Instalación

Ocultar thumbs Ver también para ZV750:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION – VENTED TO THE OUTSIDE
5
CONNECT DUCTWORK
■ Remove shipping tape from the damper.
■ Install ductwork, making connections in the direction
of airflow as illustrated.
■ Push duct over the exhaust outlet and damper.
Duct tape
over seam
and screw
CAUTION
Do not use sheet metal screws at the
exhaust outlet connection. Doing so will prevent proper
damper operation. Seal connection with tape only.
■ Secure joints in ductwork with sheet metal screws.
■ Wrap all duct joints and the flange connections with
aluminized duct tape for an airtight seal.
12
Installation Instructions
Airflow
Screw
6
CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING
If house wiring is not 2-wire with
a ground wire, a ground must be provided by the
installer. When house wiring is aluminum, be sure
to use U.L.-approved antioxidant compound and
aluminum-to-copper connectors.
■ Remove the junction box cover and the selected
knockout.
Knockout
Junction
box cover
■ Secure the house wiring to the junction box with a
strain relief (not provided).
■ Connect the white lead to the branch circuit white
lead.
■ Connect the black lead to the branch circuit black
lead.
■ Connect the green/yellow lead to the branch circuit
green lead or bare ground lead.
■ Secure all the connections with wire nuts on each
electrical connector.
■ Push the wires into the junction box and replace the
cover. Be sure the wires are not pinched.
■ Secure the junction box cover with the 2 original
screws.
31-10724-7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Zv755

Tabla de contenido