Micropulse Linear Transducer - Rod Style
4

Wiring

Note the following when mak-
ing electrical connections:
System and control cabi-
net must be at the same
ground potential.
To ensure the electromagnetic
compatibility (EMC) which Balluff
warrants with the CE Mark, the
following instructions must be
strictly followed.
BTL transducer and the proces-
sor/control must be connected
using shielded cable.
4.1

Connector S32

BKS Connector,
View of solder end
of connector body
BKS-S32M-00
or BKS-S33M-00
Fig. 4-1: Pin arrangement BKS on
BTL
Pin
BTL5-S1_ _...S32
Interface signals
1
+Clk
2
+Data
3
–Clk
4
do not connect
5
–Data
Supply voltage (external)
6
GND
7
+24 V
8
do not connect
Table 4-1: Wiring
4.3

Cable KA_ _

+Clk
–Clk
+Data
–Data
GND
+24 V
BTL5-S1_ _
Fig. 4-3: BTL5-S1_ _-...KA_ _ with Processor/Controller, Connection example
6
english
Shielding: Copper filament
braided, 85 % coverage.
The shield must be tied to the
connector housing in the BKS
connector; see instructions ac-
companying the connector.
In the cable version the cable
shield is connected to the housing
in the PG fitting.
The cable shield must be
grounded on the control side, i.e.,
connected to the protection
ground.
4.2

Connector S147

BKS Connector,
View of solder end
of connector body
BKS-S147M-00
or BKS-S148M-00
Fig. 4-1: Pin arrangement BKS on
BTL
Pin
BTL5-S1_ _...S147
Interface signals
1
–Data
2
+Data
3
+Clk
4
–Clk
Supply voltage (external)
5
+24 V
6
GND
7
do not connect
Table 4-2: Wiring
YE
PK
GY
GN
BU
BN
Processor/
Controller
Pin assignments can be found in
➥ ➥ ➥ ➥ ➥ Table 4-1, 4-2 or 4-3. Connec-
tions on the controller side may
vary according to the controller
and configuration used.
To avoid coupled noise, avoid
proximity to high-current lines
when routing cable between
transducer, controller and power
supply. Inductive coupled noise
from AC harmonics (e.g., from
phase controls) are especially
critical, against which the cable
shield offers very little protec-
tion.
Caution! False data will result
from reversing the +Clk and –Clk
inputs.
Colors
BTL5-S1_ _...-KA_ _
Interface signals
YE yellow
+Clk
PK pink
-Clk
GY gray
+Data
GN green
–Data
Supply voltage (external)
BU blue
GND
BN brown
+24 V
WH white
do not connect
Table 4-3: Wiring