Technical Data; Dimensions, Weights, Ambient Conditions; Supply Voltage (External); Control Signals - Balluff Micropulse BTL5-S1 Serie Manual De Instrucciones

Transductor de desplazamiento
Ocultar thumbs Ver también para Micropulse BTL5-S1 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

BTL5-S1_ _-M_ _ _ _A/B/Z-S32/S147/KA_ _
Micropulse Linear Transducer - Rod Style
8

Technical Data

Typical values at DC 24 V, room temperature and BTL with nominal length of 500 mm. Ready for operation at once,
full accuracy after warm-up. With magnet BTL-P-1013-4R, BTL-P-1013-4S or BTL-P-1012-4R:
Resolution (LSB)
depending on version:

BTL5-S1 _1...

1 µm
BTL5-S1 _2...
5 µm
BTL5-S1 _3...
10 µm
BTL5-S1 _4...
20 µm
BTL5-S1 _5...
40 µm
BTL5-S1 _6...
100 µm
BTL5-S1 _7...
2 µm
BTL5-S1 _8...
50 µm
Non-linearity
for resolution < 10 µm
for resolution > 10 µm
Output data
Update rate f
max
Hysteresis
Repeatability
(resolution + hysteresis)
Temperature coefficient
< (6 µm + 5 ppm * nominal length)/K
Shock loading
100 g/6 ms
1
per IEC 60068-2-27
Continuous shock 100 g/2 ms
per IEC 60068-2-29
1
Vibration
12 g, 10 to 2000 Hz
per IEC 60068-2-6
1
(take care to avoid inherent reso-
nances of protective tube)
Pressure
up to 600 bar
when installed in a
hydraulic cylinder
1
Individual specifications as per
Balluff factory standard
The CE Mark verifies
that our products meet
the requirements of
EC Directive
89/336/EEC (EMC Directive)
and the EMC Law. Testing in our
EMC Laboratory, which is accred-
ited by DATech for Testing Electro-
magnetic Compatibility, has con-
firmed that Balluff products meet
the EMC requirements of the fol-
lowing Generic Standards:
EN 61000-6-4 (emission)
EN 61000-6-2 (noise immunity)
8.1
Dimensions, weights,
ambient conditions
Nominal length
Dimensions
Weight
Housing
Pressure tube
Diameter
Wall thickness
± 30 µm
E-modulus
± 2 LSB
Mounting threads
M18×1.5 or 3/4"-16UNF
< 2 kHz
Operating temp.
Humidity
< 1 LSB
< 2 LSB
Protection rating
per IEC 60529
when closed up
8.2

Supply voltage (external)

Regulated supply voltage
BTL5-_1...
Ripple
Current draw
Inrush
Polarity reversal
protection
Overvoltage protection
Transzorb diodes
Electric strength
GND to housing
Emission tests:
RF Emission
EN 55011 Group 1, Class A+B
Noise immunity tests:
Static electricity (ESD)
EN 61000-4-2
Electromagnetic fields (RFI)
EN 61000-4-3
Fast transients (Burst)
EN 61000-4-4
Surge
EN 61000-4-5
Line-induced noise induced by
high-frequency fields
EN 61000-4-6
Magnetic fields
EN 61000-4-8
8.3
Interface
< 4000 mm
Clock input
➥ ➥ ➥ ➥ ➥ Fig. 3-1
(via optical coupler)
approx. 2 kg/m
Clock frequency
anodized
Output data
aluminum
Position
Stainless steel
information
1.4571
10.2 mm
8.4
2 mm
+Clk, –Clk, +Data, –Data, 24 V, GND
approx. 200 kN/mm
2
Cable, twisted-pair, shielded
max. length 400 m, Ø 6 to 8 mm
–40 °C to +85 °C
The clock frequency is a function
< 90 %,
of the cable length:
non-dewing
Cable length
IP 67
< 25 m
< 50 m
< 100 m
< 200 m
< 400 m
DC 20 to 28 V
< 0.5 V
pp
Table 8-1: Clock frequency
< 90 mA
< 3 A/0.5 ms
built-in
500 V
Severity level 3
Severity level 3
Severity level 3
Severity level 2
Severity level 3
Severity level 4

Control signals

RS 485/422
+Clk, –Clk
max. 1000 kHz
+Data, –Data
24 or 25 bit serial

Connection to processor

Clock frequency
< 1000 kHz
< 500 kHz
< 400 kHz
< 200 kHz
< 100 kHz
UL authorization
File No.
E227256
english