The air pressure in the air network:
MUST BE MAXIMUM 10 BAR
THE EQUIPMENT "COMPACT 220"
IS ADJUSTED ON 4 BAR
12.1. INITIAL AUTOMATIC WASHING
At the end of painting and to get a longer duration
of the solvent in the machine is recommended to
eliminate the excess of paint and a small manual
prewash before entering spray guns in the
machine.
Open the lid and place the spray gun and
accessories as indicated in the picture, using the
plastic clip of the opening trigger that comes on
the machine and placed in the air inlet of the
pneumatic device protection. Close the lid.
Press the power button ON / OFF system. Set the
timer by turning it of clockwise.
STARTING AND STOPPING SYSTEM
While in ON position the extraction of machine
will be on
The total amount of solvent introduced to clean
recirculation and cleaning solvent should not
exceed the total capacity of the bottle containing
the solvent for recirculation to prevent overflow.
12. INSTRUCTIONS FOR USE
Downward vertical: dirty solvent. (The recycled solvent) only
If during the washing time the operator opens the
lid the pump will stop automatically. Anyway, do
not open cover during washing to avoid splashing.
Completed the washing time the pump will stop
and the suction vapor will start.
12.2. FINAL AUTOMATIC WASHING
Place the working solvent selection lever down
way. Press the cleaning button. While pressing the
pump will send clean solvent to the jets.
- 17 -
WARNING:
The pump should never work empty.
WARNING:
WORKING SOLVENT SELECTION LEVER
automatic work with timer
TIMER
The recirculation of the machine only works when
the timer is running and the lid close