9a
Before continuing, determine the type of water supply connecation you have from
the chart below and use the appropriate assembly parts required to properly
reconnect the water supply. DO NOT use plumber's putty to seal these fittings.
METAL / COPPER
METAL FLANGED
FLARED TUBING
TUBING
LOCK NUT
CONE
WASHER
COUPLING
NUT
WATER
SHUT-OFF
These parts must be used as
illustrated to insure water-tight
connection. Use of existing
coupling nut may result in water
leakage. Water supply tube or pipe
must extend at least 1/2" inside
threaded shank of valve (does not
apply to flanged tubing).
CAUTION: DO NOT USE
CONE WASHER WITH
PLASTIC SUPPLY LINE.
WARNING: Do not use plumber's putty, pipe dope, or any other sealant on the water supply connection to this tank. If the connection
!
leaks after hand tightening, replace the supply line. If the connection continues to leak with the new supply line, replace the fill valve.
Warranty is void if any type of sealant is used on the water supply connection.
10
TOP
CRITICAL LEVEL
MARK ("C.L.")
MUST BE
1" ABOVE
OVERFLOW PIPE
FLOAT
FILL
VALVE
VALVE
BODY
ADJUSTABLE
HEIGHT
LOCK NUT
CONE WASHER
COUPLING NUT
(HAND TIGHT ONLY)
12

CARE AND CLEANING

When cleaning your toilet, wash it with mild, soapy water, rinse thoroughly with clear water and dry with a soft cloth. Avoid detergents,
disinfectants, or cleaning products in aerosol cans. NEVER use abrasive scouring powders or abrasive pads on your toilet seat. Some
bathroom chemicals and cosmetics may damage the seat's finish.
WARNING:
Do not use in-tank cleaners. Products containing chlorine (calcium hypochlorite) can seriously damage fittings in the
!
tank. This damage can cause leakage and property damage.
American Standard shall not be responsible or liable for any tank fitting damage caused by the use of cleaners containing
chlorine (calcium hypochlorite).
METAL SPIRAL
TUBING
LOCK NUT
LOCK NUT
EXISTING
EXISTING
WASHER
CONE
WASHER
EXISTING
COUPLING
COUPLING
NUT
NUT
WATER
WATER
SHUT-OFF
SHUT-OFF
Use existing
Use existing spiral
coupling nut
cone washer.
and washer.
Fluidmaster cone
washer may not
seal completely on
spiral type supply
line.
CAUTION: Overtightening of
LOCK NUT or COUPLING NUT
could result in breakage and
potential flooding.
ARM
REFILL
NIPPLE
TUBE
TANK
LEVER
CUP
FLUSH
VALVE
WATER LEVEL
ADJUSTMENT
ROD
FLAPPER
SHANK
WASHER
THREADED
SHANK
PARTS FOR WATER
CONNECTION
(SEE STEP 9)
Diagram 1
9b
VINYL / BRAIDED
CONNECTOR
LOCK NUT
COUPLING
NUT
WATER
SHUT-OFF
Captive cone
washers already
included. No
additional washers
needed.
ADJUSTMENTS
a. Adjust water level. Water level should
be adjusted to level indicated on tank
by adjusting float cup.
See Step 11 for water level adjustment
method
b. If bowl fails to siphon, an adjustment
may be required with the lift chain.
Simply remove the bead chain from
the retainment clip and take up slack
on the chain, and reinsert on lift rod.
Make sure the chain is not too taught.
- 3 -
With correct washers in
place (see Step 9a),
tighten COUPLING NUT
1/4 turn beyond hand tight.
DO NOT OVERTIGHTEN.
11
Turn on water supply.
Submerge the FLOAT CUP
under the water for 30 seconds.
Adjust the water to desired level
by turning WATER LEVEL
ADJUSTMENT ROD and
moving FLOAT CUP up or
down.
7 30 2 4 2 7- 10 0 ( 3 / 19 )