• Connect or replace the power cable fuse.
• Replace the electronic control.
• Check and correct any possible poor contacts, breakages or disconnections of
the battery power cable.
• Connect or replace the electronic control power fuse (first take down the control
panel's front panel).
• Check and correct the position of the battery connection cables (Az with 25A fuse
to + and M to -).
!
(If the error persists, contact the Authorised Technical Service).
• Check and correct any possible poor contacts in return air sensor cables or
terminals.
• Check and correct any possible poor contacts in return air sensor cables or
terminals.
!
(If the error persists, contact the Authorised Technical Service).
• Check and correct any possible poor contacts in connections or terminals of the
battery power cable.
• Charge or replace the battery.
!
(If the error persists, contact the Authorised Technical Service).