Troubleshooting
Fault
Device does not
function, LED does
not glow.
The device does not
cool (plug is inserted,
"POWER" LED is lit).
The device does not
cool (plug is inserted,
"ERROR" LED flashes).
The display shows an
error message (e.g.
"Err1") and the appli-
ance does not cool.
10

Disposal

➤ Place the packaging material in the appropriate recycling waste
bins wherever possible.
If you wish to finally dispose of the device, ask your local recycling
centre or specialist dealer for details about how to do this in
accordance with the applicable disposal regulations.
36
All manuals and user guides at all-guides.com
Possible cause
Battery voltage is too
low.
No voltage present in the
AC voltage socket.
The device fuse is
defective.
The integrated mains
adapter is defective.
Defective compressor.
Battery voltage is too
low.
The appliance has
switched off due to an
internal fault.
Suggested remedy
Test the battery and charge it as needed.
Try using another plug socket.
Replace the device fuse, see "Replacing
the device fuse" on page 34.
This can only be repaired by an
authorised repair centre.
This can only be repaired by an
authorised customer services unit.
Test the battery and charge it as needed.
This can only be repaired by an
authorised repair centre.