Troubleshooting - Waeco CoolMatic CB-36 Instrucciones De Uso

Frigorífco empotrabe por compresor
Ocultar thumbs Ver también para CoolMatic CB-36:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
_CB_RHD_Kühlboxen.book Seite 30 Montag, 20. Dezember 2004 11:24 11

Troubleshooting

11
Troubleshooting
Compressor does not run
Fault
U
= 0 V
T
≤ U
U
T
ON
Start attempt with
≤ U
U
T
OFF
Start attempt with
≤ U
U
T
ON
Voltage between the positive and negative electronic terminals
U
T
Switch-on voltage of the electronics
U
ON
Switch-off voltage of the electronics
U
OFF
Interior temperature too low in control setting "1"
Fault
Compressor runs
constantly
Compressor runs for a
long time
30
Possible cause
The connection between the battery
and the electronics is interrupted
Main switch defective (if installed)
Additional supply line fuse has blown
(if installed)
Battery voltage is too low
Loose cables
Poor contact (corrosion)
Battery capacity too low
Cable cross section too low
Ambient temperature too high
Insufficient ventilation
Condenser is dirty
Fan defective (if installed)
Possible cause
Thermostat sensor has no contact to
the vaporiser
Thermostat defective
Short circuit in the thermostat line
A large amount has frozen solid in the
device (only CB-36, CB-40)
CB-36, CB-40, RHD-50
Remedy
Establish a connection
Replace the main switch
Replacing the fuse
Charge the battery
Establish a connection
Replace the battery
Replace the cable (6,
page 4)
Move the cooling device
Clean the condenser
Replace the fan
Remedy
Secure the sensor
Change the thermostat

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Coolmatic cb-40Coolmatic rhd-50

Tabla de contenido