s
SMV 11
Installation instructions
Fig.1
E
W
Fig.2
Fig.3
1. Product description
The circuit board SMV 11 is a module for voice alarm
transmission, help messages and audio recording for
the SI-xxx series of control panels.
2. Supply package
The SMV 11 UK package contains the following:
- One circuit board SMV 11,
- Two mounting studs,
- One SLV 11 UK language kit complete with :
- Installation instructions.
3. Mounting instructions
The circuit board SMV 11 is designed for connection
to the expansion connector of the central control unit.
It may be used also in combination with the WMA 11.
3.1 Product overview (Fig.1)
Q
- Loudspeaker U.
- Microphone Y.
- Switch I for loudspeaker (closed = active).
- Selection wheelO.
- Button E for recording.
- LED T active during recording.
- Button R for play.
- Connection Q to main circuit board or communicator
circuit board.
- Connector W for expansions.
3.2 Mounting (Fig.2)
1 - Ensure that the main circuit board is de-
energised.
2 - Engage the mounting studs E in the holes W.
3 - From above, plug in the circuit board into the
connector Q and the mounting studs E.
4. Commissioning
4.1 Recording of alarm messages (Fig.3)
1 - Select recording alarm messages through engineer
menu.
2 - Select with the selection wheel the position of the
alarm message (W Fig.3) to be recorded (1 to 6
or ID).
3 - Press record button and speak the message
towards the microphone. LED is on as long as the
recording time is not exceeded.
4 - Release the record button at the end of the
message.
5 - Check with play button if the message is OK.
Loudspeaker switch must be closed.
6 - Record next message in the same way.
7 - At the end of the recording the loudspeaker must
be disconnected by opening the loudspeaker
switch.
Alarm message 1 to 6 can be maximal 3.2 seconds
each and the identi cation of the control panel can
be maximal 6.4 seconds of duration.