BTL7-V50D/E/T-M _ _ _ _ -A/B/Y/Z(8)-C003
Transducer — Rod Style
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
Intended use
The Transducer, together with a machine controller (e.g.
PLC), comprises a position measuring system. It is
intended to be installed into a machine or system and
used in the industrial sector. Flawless function in
accordance with the specifications in the technical data is
ensured only when using original Balluff accessories. Use
of any other components will void the warranty.
Opening the transducer or non-approved use are not
permitted and will result in the loss of warranty and liability
claims against the manufacturer.
General safety notes
Installation and startup may only be performed by
trained specialists.
The operator is responsible for ensuring that local safety
regulations are observed. In particular, the operator must
take steps to ensure that a defect in the position
measuring system will not result in hazards to persons or
equipment.
If defects and unresolvable faults occur in the transducer,
it should be taken out of service and secured against
unauthorized use.

Downloading further instructions

A complete user's guide and the configuration guide can
be downloaded from the Internet at www.balluff.com or
requested via e-mail from service@balluff.de.
...-B/Z...
8
11.5
1)
Unusable area
2)
Not included in scope of delivery
Version
D1
...-A/B/Y/Z-...
10.2 mm
...-A8/B8/Y8/Z8-...
8 mm
1
english
Mounting surface
B: 30-1 mm
Z: 2"-0.04"
1)
0.5 Ø 25
109
25
G
Thread M4x4/6 deep
No thread
Dimensions and function
The transducer contains the waveguide which is protected
by an outer stainless steel tube (rod). A magnet is moved
along the waveguide. This magnet is connected to the
system part whose position is to be determined.
The descriptions of the LED displays can be
found in the comprehensive user's guide.
Installation
Interference in function
Improper installation can compromise the function of the
transducer and result in increased wear.
► The mounting surface of the transducer must make
full contact with the supporting surface.
► The bore must be perfectly sealed (O-ring/flat seal).
Screw the transducer thread into the mounting hole
(max. torque 100 Nm).
For horizontal assembly with nominal lengths > 500 mm,
support the rod and tighten it at the end if necessary (only
possible with a diameter of 10.2 mm).
If installed in a hydraulic cylinder, the magnet should not
make contact with the rod. Minimum bore diameter in the
support piston:
Rod diameter
10.2 mm
8 mm
Damping zone
Nominal length =
60
Measuring range
2)
Magnet
Thread size
B: M18×1.5
Mounting surface
Z: 3/4"-16UNF
...-A/Y...
File no.
E227256
NOTICE!
Bore diameter
At least 13 mm
At least 11 mm
1)
45.2
46
A: 30-1 mm
Y: 2"-0.04"
1)
Thread size
A: M18x1.5
109
25
Y: 3/4"-16UNF