MAINTENANCE AND USE MANUAL
Fig. 3: Screw the adapter with rapid female coupling
onto the "CATALYST" bottle.
No special tasks need to be carried out when using the 2 kg transparent cylindrical containers
(supplied on request) as they are already equipped with the relevant adapters.
To equip the machine with 5 and 10 kg cans (supplied on request), doublemix has a specially
designed lower support (9) and side brackets (10).
The side brackets have two different positions, depending on whether they have to support 5 kg or
10 kg cans. The rapid connectors on the machine are positioned on flexible supports, which allow, by
way of a simple movement, the fittings to adapt to the 5 and 10 kg cans.
Fig. 4: Unscrew the plug from the 5-10 kg "BASE" and
"CATALYST" Elite Double bottles.
Fig. 5: Screw the plug with rapid male coupling onto the
"BASE" can.
DOUBLEMIX
EN
Preparing 2 kg transparent cylindrical containers
Preparing 5 kg and 10 kg cans
CATALYST
BASE
CATALYST
5KG
10KG
BASE
5KG
10KG
Grey