OPERATION
1. Determine proper location for unit. Unit should be located so that
inlet is gravity-fed. Unit will not draw water up from a lower level.
Position and level basin. Keep basin away from any item that could
puncture basin. Position selected should be convenient to inlet,
discharge and vent piping and electrical supply.
2. Plumb inlet. Using 1½" threaded pipe, plumb discharge to basin
cover fitting. Use a P-trap and a union next to the basin. Use pipe
joint compound and hand tighten only on plastic fittings. Do not
reduce below 1½" piping.
3. Plumb discharge. Using 1½" threaded pipe, plumb discharge to
basin cover fitting. Use a swing check valve no more than 3" from
top of basin cover and union. Be sure check valve is installed in
proper flow direction. If check valve is installed backwards, no water
will flow out of unit. Be sure discharge piping is sealed with pipe joint
compound and that lift height of pump is not exceeded. Hand
tighten only on plastic fitting.
4. Plumb vent. Plumb vent using 2" threaded pipe to fitting in basin
cover. Use pipe joint compound on threads and hand tighten only
on plastic fittings. The basin must be vented in accordance with
state and local codes. The vent is essential for proper switch
operation and must not be omitted or restricted.
THIS UNIT WILL NOT OPERATE WITHOUT PROPER VENTING.
CAUTION: Do not use a mechanical vent with this product. A
mechanical vent will cause improper operation of the automatic switch.
5. Test Unit. Connect power cord to electrical supply as stated under
"Electrical Connections." Secure power cord to piping with ties or
tape. Fill unit with water through inlet.Pump should turn on with 4" to
7" of water in tank, and turn off when 1½" to 3½" of water is left in tank.
SERVICE INSTRUCTIONS
MAKE CERTAIN THE UNIT IS DISCONNECTED FROM THE
POWER SOURCE BEFORE ATTEMPTING TO SERVICE OR
REMOVE ANY COMPONENT!
1. To clean inlet filter remove the (4) screen cover plate screws (item
21), cover plate (item 29), o-ring (item 28) and screen (item 27).
Clean inlet screen using a mild detergent and water. Examine o-ring
and if deformed, replace with new o-ring. See replacement parts list.
2. Sediment may build up in basin causing pump to operate
improperly. Remove (10) 1/4-20 screws (item 21) from cover.
Remove cord grommet and loosen cords to allow slack and then
remove cover.
2
TYPICAL INSTALLATION
INSTALLATION TYPE
Remove pump and clean basin using a mild detergent and water.
Reassemble in reverse order. Torque screws (item 21) 18–20
in–lbs.
3. If pump alignment plate is removed, it must be reinstalled per pump
alignment diagram.
4. Sediment or lint can clog pump and cause improper operation. If
necessary, remove pump and pull off the pressed-in screen, clean
using a mild detergent and water, and reinstall. Plastic pump base
may also be removed to clean around impeller and inside base.
Remove the six base screws and clean base using a mild
detergent and water. Do not remove impeller. When reinstalling
base, be sure seal ring is seated properly in groove and torque
screws to 12-17 in.-lbs. See pump manual for other information.
For any other pump repair, return the pump to a Little Giant
authorized service center.
5. This unit is permanently lubricated. Oiling is not required. Do not, in any
case, open the sealed portion of the unit or remove housing screws.
6. Remove screws (item 4) that hold base to volute and clean impeller
and volute passage. Do not use strong solvents on impeller.
7. Be sure impeller turns freely after cleaning. WARNING: DO NOT
REMOVE IMPELLER. REMOVAL OF IMPELLER REQUIRES
SPECIAL TOOLS AND IS TO BE DONE ONLY BY AN
AUTHORIZED SERVICE CENTER.
8. When reinstalling base, be sure seal ring is seated properly in
groove and torque screws (item 4) to 10–15 in.–lbs.
9. DO NOT REMOVE MOTOR HOUSING COVER. WARRANTY IS
VOID IF MOTOR HOUSING COVER, IMPELLER OR SEALS HAVE
BEEN REMOVED. ANY REPAIR ON MOTOR MUST BE DONE BY
AN AUTHORIZED LITTLE GIANT SERVICE CENTER.
10. Be certain power cord is in good condition and contains no nicks
or cuts.
SPECIFICATIONS
AMPS
MODEL
CAT.
VOLTS HERTZ
NO.
NO.
S
WRSC-6 506065 115
60
13
WRSC-6 506066 230
50
7
F INTRODUCTION
Cette liste de directives vous fournit les renseignements nécessaires
pour utiliser une WRSC-6 Little Giant en toute sécurité. Cette pompe est
conçue pour pomper les eaux usées des bacs à linge sale, des
machines à laver, des éviers ou des déshumidificateurs.
GALLONS PER HOUR
SHUT
(GPH) AT HT.
WATTS
OFF
(FT.)
R
5'
10'
15'
9
720
2750
1750
750
18
5
720
2580
1050
12
MAX.
PSI
7.8
5.2