Power supply
Operating voltage range DC
Nominal operating voltage DC
Intrinsic current consumption at 24 V
(without connected devices)
– from operating voltage supply for electronics/
sensors (U
EL/SEN
Maximum current consumption per I-port at 24 V
– PS, from operating voltage supply,
electronics/sensors (U
– PL, from load voltage supply, valves (U
Electrical isolation
– Between operating voltage supply,
electronics/sensors PS (U
load voltage supply, valves PL (U
– Supply PS/PL between the I-ports
Festo CPX-CTEL-Z6 1411a English
)
)
EL/SEN
) and
EL/SEN
VAL
18 ... 30 V
24 V
typ. 65 mA
1.6 A
)
1.6 A
VAL
yes, with potential-
isolated supply
)
no
23