3 Repeat the process for the rack-mounting bracket on the other side of the
switch.
4 Insert the switch into the 48.26 cm (19 inch) rack, ensuring that the rack-
mounting holes on the switch line up to the mounting holes in the rack.
5 Secure the switch to the rack with either the rack bolts or cage nuts and
cage-nut bolts with washers (depending on the kind of rack you have).
Fasten the bolts on bottom before fastening the bolts on top.
CAUTION:
rack.
NOTE:
Make sure that the ventilation holes are not obstructed.
Installing as a Free-standing Switch
NOTE:
Dell strongly recommends mounting the switch in a rack.
Install the switch on a flat surface if you are not installing it in a rack. The
surface must be able to support the weight of the switch and the switch
cables. The switch is supplied with four self-adhesive rubber pads.
1 Attach the self-adhesive rubber pads on each location marked on the
bottom of the switch.
2 Set the switch on a flat surface, and make sure that it has proper
ventilation by leaving 5 cm (2 inches) on each side and 13 cm (5 inches) at
the back.
Stacking Multiple N2128PX-ON Switches
You can stack N2128PX-ON switches up to 12 switches high using the mini-
SAS ports located on the rear of the switch. When multiple switches are
connected together through the stack ports, they operate as a single unit with
up to 336 front panel ports. The stack operates and is managed as a single
entity. Refer to the User Configuration Guide and the CLI Reference Guide for
more information.
10
Getting Started Guide
Make sure that the supplied rack bolts fit the pre-threaded holes in the