Button Functions; Auto Power Off Function - koban KMD 05 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Display
1. AC (alternating current)
2. Polarity indicator
3. DC (direct current)
4. Auto range
5. Data hold
6. Diode measurement
7. Continuity measurement.
8. Low battery indicator
9. Reading display
10. Measurement units

Button functions

FUNC button:
• Press FUNC to switch between AC/DC or between functions.
HOLD button:
• Press HOLD to keep the current reading on screen.
DATA H symbol will appear on the display.
• Press HOLD again to release the hold.
RAN button:
• Press RAN to switch to manual range. Each press of the button will switch
to the next highest range, until reaching the highest range where it will
switchto the lowest range.
• Hold RAN to return to auto range.
NCV button:
• Hold the NCV button down in any mode and the meter will activate the
non-contact voltage detection.
• Hold the meter up to a voltage source and the buzzer will sound and the
NCV indicator will light up if the voltage is detected.
• Release the NCV button to stop NCV detection.

Auto Power Off function

• After 15 minutes of non-use the meter will automatically turn itself off.
• To turn the meter back on, press any button or turn the rotary switch to any
position.
• To deactivate the auto power off functioon, hold down HOLD when turning
on the meter.
www.grupotemper.com
KMD 05
Digital multimeter
Instructions manual |
19

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido