6 INITIAL SETUP FOR A NEW SYSTEM – MINIMUM SETUP
Upon installation of a new system, several items need to be configured before the system will operate properly . The items that must be configured for
proper operation are:
• Assignment of controller to valve
• Valve Calibration
Other options, such as units of measure, valve name, display brightness etc ., can be configured at any time via the Setup Menu, but are not required for
proper system operation during initial installation .
Assigning a Valve
Before controlling a valve or displaying sensor readings, the Style 9323 Navigator Pro must be assigned to a valve . This step tells the display what valve
it is controlling. In order for the assignment to take place, the desired valve must be powered and connected to the Navigator Pro via a CAN network (see
the "GENERAL INSTALLATION" section above for wiring instructions). Valve assignment will only need to be performed once and can be changed at a
later time via the Setup Menu if required .
There are two ways to assign a valve: automatically or manually. If there is only one valve installed on the CAN network (e.g. one or more display(s) are
connected directly to one valve), all displays on the network will automatically be assigned to that valve. If there is more than one valve on the network,
the appropriate valve will need to be selected manually . There are two opportunities to select the valve manually:
• At first power up.
• At any time from the Setup Menu (see the "VALVE ASSIGNMENT" section below).
When the assignment process begins (either at startup or through the Setup Menu), the Navigator Pro will display a list of serial numbers of all powered
valves connected via the CAN network . The serial numbers in the list correspond to the labels affixed to each valve as shown below .
Valve Serial number location
RED and
GREEN buttons to scroll through the list until the desired valve serial number is highlighted . Then press the ■ SET button to
Use the
assign the selected valve .
Note: The Navigator Pro cannot be assigned to more than one valve. The Navigator Pro will remember its as-
signed valve even when the power is off.
Once the Navigator Pro has been successfully assigned to a valve, the screen will proceed to the main operational screen . The Navigator Pro can now be
used to open and close the valve . However, valve calibration must be performed in order to display valve position properly .