The Navigator Pro system can also be installed in a networked configuration . Since the system operates on a CAN protocol, as long as the valve is
on the network, it can be paired with the appropriate 9323(s) (see ASSIGNING A VALVE section
Auxiliary Displays
The Navigator Pro system can be easily setup with multiple displays controlling one valve . As long as the display is on the same CAN network as the
valve it is controlling, the valve can be assigned to that display . A single valve can be easily assigned to as many as 10 displays .
9-7/8"
5.1 ELECTRICAL INSTALLATION
Voltage Requirements:
The system has been designed to work on 12VDC or 24VDC systems . It will operate properly if the voltage is between 10VDC and 32VDC AT THE MO-
TOR . System voltage is not an adequate measurement to determine if the voltage is appropriate at the motor . To avoid excessive voltage drop and unde-
2-23/32"
sired operation, the wire gauge should be 14 AWG or larger and the distance from power source to the motor should be no more than 20ft.