This certificate for the HP200 surface treatment is based on
documented test procedures on material resistance
defined product specifications
a standardized cleaning procedure
Test procedure
Dipping test:
•
Immersion into the test medium with contact surface
toward ambient air
Test period:
•
7 days
The HP200 surface treatment was tested in the following media:
Alkaline and chlorinated foam cleaners
P3-topax 19
P3-topax 686
Acid foam cleaning agents
P3-topax 56
P3-topax 58
Product specifications:
P3-topax 19
Alkaline foam cleaning agent
P3-topax 56
Acid foam cleaning agent based on phosphoric
acid
P3-topax 58
Acid foam cleaning agent based on organic
acids
P3-topax 686
Alkaline foam cleaning agent with active chlorine
P3-topactive 200
Alkaline cleaning agent for operational cleaning as
TFC application
Instrucciones de funcionamiento – MOVIGEAR
Datos técnicos y hojas de dimensiones
5%
40°C
o
5%
40°C
o
5%
40°C
o
5%
40°C
+
®
-DSC-B
Versión para zonas húmedas
Evaluation:
•
Evaluation approx. 7 days after regeneration
•
Evaluation of changes of the protective properties
according to DIN EN ISO 4628-1
•
Evaluation of decorative changes (color, brightness,
blistering)
(+) no changes
(o) possible minor changes
(-) possible changes under long-term influence
TFC cleaning agents
P3-topactive 200
4%
P3-topactive 500
4%
Disinfectants
P3-topax 990
5%
P3-topactive DES
3%
P3-oxysan ZS
1%
DI water
-
P3-topactive 500
Acid cleaning agent for operational cleaning as
TFC application
P3-topax 990
Alkaline foam disinfectant based on alkylamine
acetate
P3-topactive DES
Foam and TFC capable disinfectant based on
H
O
and peroxy acid
2
2
P3-oxysan ZS
Disinfectant based on peroxy compounds
DI water
Demineralized water
n
kVA
f
i
P
Hz
40°C
o
40°C
o
23°C
+
23°C
+
23°C
+
40°C
+
9007201867251979
12
247