Description
The ZL150 control panel is suitable for con-
trolling automatic systems for the FLEX se-
ries swing gates powered by 24V d.c. with
capacity up to 48 W, frequency 50-60 Hz.
Wholly designed and built by CAME S.p.A., it
meets UNI 8612 regulations in force. ABS
case, which has an IP54 protection level,
with air recycling inlet.
The circuit requires 230V (a.c.) at terminal
blocks L1-L2 and the inlet is protected with
5A fuse. A 1,6A fuse protects the low voltage
command devices.
The accessories' total wattage (24V) must
not exceed 40W.
Safety
Photocells can be connected to obtain:
- Re-opening during closure (2-C1), if the
photocells identify an obstacle while the gate
is closing, they will reverse the direction of
movement until the gate is completely open;
- Re-closing during opening (2-CX, dip
8OFF-10OFF), if the photocells identify an
obstacle while the gate is opening, they will
reverse the direction of movement until the
gate is completely closed;
- Partial stop, shutdown of moving gate, with
activation of an automatic closing cycle (2-
CX, dip 8OFF-10ON);
- Total stop (1-2), shutdown of gate
movement without automatic closing; a
pushbutton or radio remote control must be
actuated to resume movement.
NB: If an NC safety contact (2-C1, 2-CX, 1-2)
is opened, the LED will flash to indicate this
fact.
Accessories which can be connected to
this unit
- Gate open pilot lamp (3W). A lamp that sig-
nals the gate's open position and that goes
out when the gate is in the closed position.
Connected to terminals 10-5.
- Electric lock (2-S);
- LB54 Board. Powers the reduction gears
through batteries in case of a power outage.
After the power supply is restored, it also re-
charges the batteries.
GENERAL CHARACTERISTICS
Other functions available
- Automatic closing. The automatic closing
timer is automatically activated at the end of
the opening cycle. The preset, adjustable
automatic closing time is automatically
interrupted by the activation of any safety
system, and is deactivated after a STOP
command or in case of power failure;
- Obstacle presence detection: When the
motor is stopped (gate is closed, open or
half-open after an emergency stop
command), the transmitter and the control
pushbutton will be deactivated if an obstacle
is detected by one of the safety devices (for
example, the photocells);
- Hammer movement. At every opening com-
mand, the wings press the closing stop-ledge
for a second, thus facilitating the release op-
eration of the electric lock connected to ter-
minals 2-S.
It is only active if the wings are closed and at
the end of the work time or at the 1
noeuvre after the system has been powered;
- "Operator present" function: Gate operates
only when the pushbutton is held down (the
radio remote control system is deactivated);
- Partial opening, second motor door
opening, adjusted with TR2M trimmer; it is
activated by collecting to the terminals 2-3P;
- Pre-flashing for 5 seconds, while the door is
opening and closing;
- Type of command:
-open-stop-close-stop for pushbutton and
radio transmitter;
-open-close-reverse for pushbutton and radio
transmitter;
-open only for radio transmitter.
Adjustments
- Automatic closure time;
- Partial opening time and delay in closing of
the M2 motor;
- Operating time.
Important! Disconnect the unit
from the main power lines before
carrying out any operation inside the
unit.