Description of control panel
Control panel for 24V d.c. gear motors, pow-
ered by 230V a.c. at 50-60 Hz (single-phase).
Designed to control single FERNI, EMEGA,
and FROG gear motors .
Designed and built entirely by CAME CAN-
CELLI AUTOMATICI S.p.A. to meet safety
standards at an IP 54 protection level.
Housing in ABS.
Guaranteed 24 months, unless tampered
with.
This control panel is powered by 230V a.c.
across terminals L1 and L2, and is protect-
ed by a 3.15A-F fuse on the main power line.
Control systems are powered by low voltage
and protected by a 630mA-F fuse.
The total power consumption of 24V acces-
sories (which are protected by a 3.15A-F
fuse) must not exceed 40 W.
In addition to normal endstop slowing when
closing and opening, the control panel also
allows slowed-down initial opening and
closing movements. The ADT card (sup-
plied in the control panel box) manages these
slower movements, also decreasing the
amount of connection cables (see
pages 20/21).
Safety
Photocells can be connected to obtain:
- Re-opening during the closing cycle (2-C1),
if the photocells identify an obstacle while
the gate is closing, they will reverse the di-
rection of movement until the gate is com-
pletely open;
- Partial stop, shutdown of moving gate, with
activation of an automatic closing cycle
(2-C3);
-4-

GENERAL CHARACTERISTICS

- Total stop (1-2), shutdown of gate move-
ment without automatic closing; a pushbut-
ton or radio remote control must be actuated
to resume movement).
- The electrical panel includes an ampero-
metric sensor for the motor which is triggered
whenever an obstacle blocks movement dur-
ing opening or closing.ù
It normally inverts the direction of movement,
but if it activates when the gate is 5 cm from
being fully close or open, it completely halts
the movement (also see adjusting the OP
TIME trimmer page 23).
The sensor's sensitivity can be adjusted
using the trimmers (see page 27).
Warning! If an obstacle is detected two times
in a row during the closing phase (and when
the Automatic Closing function is on), the
operator will:
To reactivate the operator, send a "close com-
mand" by pushing the buttons connected on
2-3, 2-3P and 2-7 (only the button).
- The transformers are equipped with a guard
that will keep the doors open in case of ther-
mal overload .
They are closed again only after the temper-
ature falls below the overload threshold.
1) it inverts the motion, completely open-
ing the gate;
2) it deactivates the Automatic Closing;
3) Block all functions of the control panel.