Programming The Artromot®-Sp3 Comfort Models - ARTROMOT SP3 Instrucciones De Uso

Ocultar thumbs Ver también para SP3:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 116
Synchronized:
Motors A and B perform a synchronized
movement according to the ankle joint's
physiological motion pattern:
From the middle position the carriage
first goes to the maximum eversion value.
Afterwards, the carriage will simultane-
ously move to the maximum inversion
value and to the maximum plantar
flexion value, and then simultaneously to
the maximum dorsal extension value and
to the value halfway between inversion
and eversion. After reaching this position,
the cycle restarts: maximum eversion at
the same time as halfway between dorsal
extension / plantar flexion, etc.
During operation the synchronized mode
is indicated in the top left-hand corner by
the symbol
.
non-synchronized:
Both motors run independently of each
other within the selected ranges of
motion.
To enable the non-synchronized mode,
disable the synchronized mode.
During operation the non-synchronized
mode is indicated in the top left-hand
corner by the symbol
Default setting: synchronized mode
enabled
Caution!
m
Patient hazard –
The synchronized operation is recom-
mended as a general rule. However,
medical and/or therapeutic indications
may call for the non-synchronized
mode. In the non-synchronized mode,
particular caution and attention on
the part of the physician/therapist is
required to rule out any risk for the
patient.
n Total therapy time
ARTROMOT®-SP3 models without
chip card
The total therapy time is the added sum
of operating hours. If the device is used by
only one patient, this time is equivalent
to the duration of all the patient's therapy
sessions.
Under menu item "total therapy time"
of ARTROMOT®-SP3 models with chip
card, you can view each patient's total
therapy time (duration of all the patient's
therapy sessions).
Deleting the stored therapy time
Press and hold the parameter button for
5 seconds or select the New Patient
function.
n Service MENU
For service purposes only, refer to Service
Manual.
Reminder:
You save the set parameter values by
pressing the STOP button.
5.4 Programming the
ARTROMOT®-SP3 Comfort models offer
two more programming levels for additional
functions.
The programming levels are selected in the
same way as on Standard models.
Programming levels 1, 2, 3 and 6 are identi-
cal with programming levels 1 to 4 of the
.
Standard models.
All special functions are disabled in the
default settings.
The following treatment values, settings
and information can be entered/viewed on
the control pendant (22):
LEVEL 1:
– Dorsal extension
– Plantar flexion
– Inversion
– Eversion
LEVEL 2:
– Pause
– Timer (therapy time)
− Speed
– New patient
59