INTEGRAL POWER
EN
G
The capacitor fan/s not working.
H
The unit works but does not cool.
I
The unit does not cool properly.
J
The blower does not work.
K
The unit does not respond to user
selection orders.
Symptom
• Capacitor fan / s blocked or damaged.
• Electronic control defective.
• Terminals disconnected.
• The compressor does not work.
• Unit without load.
• Blockage in the circuit.
• Electronic module compressor defective
or faulty connection.
• Pressure switch defective or terminals
poorly connected.
• Relay or cable relay defective or terminals
poorly connected.
• Terminals poorly connected.
• Excess or defect of gas load.
• Recirculation blocked or partially blocked.
• Capacitor/electro grille dirty.
• Capacitor fans defective.
• Capacitor fans with reversed polarity.
• Failure in the electronic control.
• Blower defective or terminals disconnected.
• Electronic control or control panel
defective.