7.3
ELETRODE MODE SELECTION
1
7
7.4

REGULATION WITH REMOTE CONTROL

The welding current can be remote con-
trolled in the electrode mode using the
MANUAL remote control.
1. Connect the 7-pin Plug of the remote
control to the Receptacle (10).
The display will blink for a few seconds.
6
GB
NOTE:
numbers
shown
below are referring to Fig. 1
chapter
6
COMMANDS
DESCRIPTION to Page 4.
1. Turn ON the generator by
turning the switch (13) in
position "1".
2. Press the pushbutton (1)
until the LED (9) lights up.
3. Turn the knob (7) to re-
gulate the welding current
value.
The value is visualized on
the digital display.
2.
remote control.
NOTE: the welding current is regulated
from the minimum current of the machine
to the set current on the display.
Ex. If the I2 set current is 200A, the regu-
lation will be from 5A to 200A.
7.5
"VRD" FUNCTION ACTIVATION
CRONOS SERIES
Set the welding current using the
VRD = Voltage Reduction
Device. If active, this fun-
ction reduces the no load
voltage of the machine to a
safe value (< 24V DC) as in
5
accordance with the interna-
tional standards.
1. Press the pushbutton (5)
to activate or disable the
"VRD" function.
2. The LED (6) will appear
green or red:
RED = "VRD" disabled
GREEN = "VRD" active
NOTE: if the machine is tur-
ned OFF with the VRD fun-
ction active, it will be ON at
the next start-up.