Function
Capacitance
Frequency Hz
Duty Cycle %
Temp. °F
Temp. °C
Continuity
Diode test
NCV
1. Overload Protection: 1000VRMS MAX Fuses FF 0.6A 1000V and FF 11A 1000V
2. Accuracy a is % of reading and b is LSD (Least Significant Digit).
Range
61-347 & 61-357
600.0nF
6.000uF
60.00uF
600.0uF
6000uF
9.999Hz ~ 9.999KHz
0.1%~99.9%
-40~1832°F
-40~1000°C
40-600V
Resolution
0.1nF
0.001uF
0.01uF
0.1uF
1uF
0.001Hz ~
0.1KHz
0.1%
±(2.0%+7)@-40~32°F
1°F
±(2.0%+6)@33~1832°F
1°C
±(2.0%+3)@1~1000°C
illuminates continuously
0.1 Ω
≥70Ω : No buzzer beep
0.001V
≥40V/(50~60Hz), with direct wire contact,
red indicator LED flashes at a frequency of
3Hz , and the buzzer beeps at a frequency
of 3Hz simultanously
Accuracy
±(a%+b)
±(5%+15)
±10%
±(0.5%+5)
±(2.0%+4)@-40~0°C
≤10Ω : Buzzer beeps
and red indicator LED
Silicon PN joint with
forward voltage about
0.5V to 0.8V
25