Haier AP24UFAHRA Manual De Funcionamiento Y Manual De Instalación página 2

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Contents
.......................................................................................................
PARTS AND FUNCTIONS
OPERATION............................................................................................................................
INDOOR AND OUTDOOR UNIT INSTALLATION..................................................................
CAUTIONS.............................................................................................................................
MAINTENANCE
.......................................................................................................................
TROUBLE SHOOTING...........................................................................................................19
Read the precautions in this manual
carefully before operating the unit.
Keep this manual where the user can easily
d it.
WARNING:
·
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
·
The appliance must be stored in a room without continuously operating ignition sources (for
example: open flames, an operating gas appliance or an operating electric heater).
·
Do not pierce or burn.
·
Be aware that refrigerants may not contain an odour.
·
The appliance must be installed, operated and stored in a room with a floor area larger than
3m.
·
2
If the supply cord is damaged, it must be replaced by the manufacturer,its service agent or
similarly qualified persons in order to avoid a hazard.
·
This appliance can be used by children aged 8 years and above and persons with reduced
physical, sensory or mental(
mentao) capabilities or lack of experience and
knowledge if they have been given superivision or instruction concering use of the
appliance in a safe way and understand the hazards involved. Children shall not play with
the appliance.
·
The appliance shall be installed in accordance with national wiring regulations
·
All the cables shall have got the European authentication certificate. During installation, when the
connecting cables break off, it must be assured that the grouding wire is the last one to be broken off.
The explosion-proof breaker of the air conditioner should be all-pole switch. Distance between its two
contacts should be not less than 3mm. Such means fordisconnection must be incorporated in the
·
wiring.
Make sure installation is done according to local wiring regulation by professional persons.
·
Make sure ground connection is correct and reliable.
·
A leakage explosion-proof breaker must be installed.
·
Do not use a refrigerant other than the one indicated on the outdoor unit(R32) when installing,
moving or repairing. Using other refrigerants may cause trouble or damage to the unit, and
personal injury.
1
Loading and Unloading/Transporting Management/Storage Requirements
1)
The products shall be carefully handled during loading and unloading.
2)
Rude and barbarous handling such as kicking, throwing, dropping, bumping, pulling and rolling is not
allowed.
3)
The workers engaged in loading and unloading must be subject to necessary trainings on the potential
hazards caused by barbarous handling.
4)
Dry powder extinguishers or other suitable fire extinguishing apparatus within the period of validity shall be
equipped at the loading and unloading site.
5)
The untrained personnel cannot be engaged in loading and unloading of flammable refrigerants air
conditioner.
6)
Before loading and unloading, anti-static measures shall be taken, and phones cannot be answered during
loading and unloading.
7)
Smoking and open fire are not allowed around the air conditioner.
Transporting Management Requirements
1)
The maximum transporting volume of finished products shall be determined as per local regulations.
2)
The vehicles used for transporting shall be operated as per local laws and regulations.
3)
Dedicated after-sales vehicles shall be used for maintenance, and exposed transporting of refrigerant
cylinders and the products to be maintained is not allowed.
4)
The rain cover or similar shielding material of transporting vehicles shall be provided with certain flame
retardancy.
5)
Leakage warning device of flammable refrigerant shall be installed inside the closed-type compartment.
6)
Anti-static device shall be equipped inside the compartment of transporting vehicles.
7)
Dry powder extinguishers or other suitable fire extinguishing apparatus within the period of validity shall be
equipped inside the driver's cab.
8)
Orange-white or red-white reflective stripes shall be pasted on the sides and tail of the transporting vehicles,
to remind the vehicles behind of keeping distance.
9)
The transporting vehicles shall run at a constant speed, and heavy acceleration/deceleration shall be avoided.
10) Combustibles or the static articles cannot be transported simultaneously.
11) High-temperature area shall be avoided during transporting, and necessary radiating measures shall be taken
in case the temperature inside the compartment is too high.
Storage Requirements
1)
The storage package of equipment used shall be such that no leakage of refrigerant will be caused due to
mechanical damage of the equipment inside.
2)
The maximum quantity of the equipment allowed to be stored together shall be determined as per local
regulations.
Installation Instructions
WARNING!
The area of the room in which R32 refrigerant air conditioner is installed cannot be less than the minimum
area specified in the table below, to avoid potential safety problems due to out-of-limit of refrigerant
concentration inside the room caused by leakage of refrigerant from refrigeration system of the indoor unit.
Once the horn mouth of connecting lines is fastened, it may not be used again (the air tightness may be
affected).
A whole connector wire shall be used for indoor/outdoor unit as required in the operation specification of
installation process and operation instructions.
Minimum Room Area
LFL
Total Mass Charged/kg
Type
kg/m3
Minimum Room Area/m
1.224
1.836
2.448
3.672
R32
0.306
3
6
13
The maximum refrigerant charge amount (M)
Unit model
M kg
Unit model
M kg
Unit model
1U20YEEFRA
0.62 1U25S2SM1FA
0.85 1U35MEEFRA
1U25BEEFRA
0.74 1U25YEMFRA
0.67 1U35S2PJ1FA
1U25BEFFRA
0.90 1U35BEEFRA
0.82 1U35S2SM1FA
1U25BEFFRA-TCS
0.90 1U35BEEFRA-TCS
0.82 1U35YEMFRA
1U25S2PJ1FA
1.15 1U35BEFFRA
0.92 1U50JEFFRA
1U42S2SM1FA
1.14 1U50S2PR1FA
1.60 1U25JEJFRA
1U50REJFRA
1.60
1U71REAFRA
1.60
2
1.
Procedures: operation shall be made as per controlled procedures to minimize the probability of risks.
2.
Area: area shall be divided and isolated appropriately, and operation in an enclosed space shall be avoided.
Before the refrigeration system is started or before hot working, ventilation or opening of the area shall be
guaranteed.
3.
Site inspection: the refrigerant shall be checked.
4.
Fire control: the fire extinguisher shall be placed nearby, and fire source or high temperature is not allowed;
the sign of "No smoking" shall be arranged.
1.
Indoor unit: nitrogen is sealed during the delivery of indoor units (inside the evaporator), and the red sign at
the top of the green plastic seal cap on the evaporator air pipes of the indoor unit shall be checked first after
unpacking. In case the sign is raised, the nitrogen sealed still exists. Afterwards, the black plastic seal cap at the
joint of evaporator liquid pipes of the indoor unit shall be pressed, to check whether nitrogen still exists. In case
no nitrogen is sprayed out, the indoor unit is subject to leakage, and installation is not allowed.
2.
Outdoor unit: the leak detection equipment shall be extended into the packing box of the outdoor unit, to
check whether the refrigerant is leaking. If the refrigerant leakage is identified, installation is not allowed, and the
outdoor unit shall be delivered to the maintenance department.
1.
The room area checked cannot be less than the area specified on the warning sign of the indoor unit.
2.
Inspection on the surrounding environment of place of installation: the outdoor unit of flammable
refrigerants air conditioner cannot be installed inside an enclosed room reserved.
3.
Power supply, switches or other high-temperature articles such as the fire source and oil heater shall be
avoided below the indoor unit.
4.
The power supply shall be provided with earthing wire and be reliably earthed.
5.
While punching the wall with an electric drill, whether embedded water/electricity/gas pipelines are
designed at the hole preset by the user shall be verified in advance. It is recommended that the through-wall holes
reserved shall be used as much as possible.
1.
Favorable ventilation shall be maintained at the place of installation (doors and windows are opened).
2.
Open fire or high-temperature heat source (including welding, smoking and oven) higher than 548
allowed within the scope of flammable refrigerant.
3.
Anti-static measures shall be taken, such as the wearing of cotton clothes and cotton gloves.
4.
The place of installation shall be convenient for installation or maintenance, and cannot be adjacent to heat
source and flammable and combustible environment.
5.
In case of refrigerant leakage of the indoor unit during installation, the valve of the outdoor unit shall be
closed immediately, and windows shall be opened, and all the personnel shall be evacuated. After the leakage of
refrigerant is handled, the indoor environment shall be subject to concentration detection. Further handling is not
allowed until the safety level is reached.
6.
In case the product is damaged, it must be delivered to the maintenance point. Welding of refrigerant
pipelines at the user's site is not allowed.
7.
The installation position of air conditioner shall be convenient for installation or maintenance. Barriers shall
be avoided around the air inlet/outlet of the indoor/outdoor unit, and the electrical appliance, power switches,
sockets, valuables and high-temperature products within the scope of both sidelines of the indoor unit shall be
avoided.
No fire source around the
Cotton clothes
Anti-static gloves
place of installation
Read operator' manual
Read technical manual
3
1
2
10
17
18
This appliance is filled with R32.
2
4.896
6.12
7.956
23
36
60
M kg
Unit model
M kg
0.82 1U50JEFFRA-TCS
1.35
1.15 1U50MEE/MFRA
1.30
1.14 1U50S2SJ2FA
1.35
0.70 1U68REE/F/MFRA
1.60
1.35 1U71S2SR1FA
1.60
0.94
1U35JEJFRA
0.94
is not
BEWARE
Goggles
ELECTROSTATICS
Operator' manual operating instructions

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido