DRIVER REPLACEMENT
1. Disconnect the air supply.
2. Loosen screw and nut with a 8mm spanner wrench
and a 4mm Allen wrench. (See Figure 15)
3. Remove the magazine assembly. (See Figure 16)
4. Loosen the set screw with a 3mm Allen wrench to
unlock the adjusting rod.
Figure 15
Figure 17
Figure 19
PAGE 8 OF 30
OPERATING INSTRUCTIONS CONTINUED
5. Slide the linkage mechanism and adjusting rod
simultaneously from the collar. (See Figure 17)
6. Loosen the screws with a 3mm Allen wrench.
(See Figure 18)
7. Take off the spring pin with a hammer and 6mm
straight rod. (See Figure 19)
Magazine Assembly
Figure 16
Figure 18
0421 IH-1030