PROBLEM
The output pres-
sure varies high
and low.
POSSIBLE
SOLUTION
CAUSE
The water supply
Open water suppy
is not sufficient.
fully. Make sure
the garden hose is
free from block-
age.
The pump absorbs
1. Make sure that
air.
the hoses and
fittings have
no problem.
2. Turn the ma-
chine off.
3. Pull the gun
trigger until a
stable flow of
water comes
out through
the nozzle.
The water intake
Remove the filter
filter is clogged.
and clean it in
warm water.
The supply volt-
Make sure that on-
age is low.
ly the pressure
washer operates
on the circuit.
The gun, hose or
Operate distilled
nozzle are calci-
vinegar through
fied.
detergent tank.
English
PROBLEM
The motor buzzes,
but you can not
start the machine.
There is no water.
8

TECHNICAL DATA

Universal Motor
Max. Pounds Per Square Inch
Pressure
Max Gallon Per Minute
Maximum Inlet Water Temper-
ature
Cleaning Units
Weight
12
POSSIBLE
SOLUTION
CAUSE
The supply volt-
Make sure that on-
age is low.
ly the pressure
washer operates
on the circuit.
The system has re-
1. Stop the ma-
maining pressure.
chine.
2. Pull the gun
trigger on
spray wand to
release pres-
sure
3. Start the ma-
chine.
The voltage de-
Disconnect the ex-
creases across ex-
tension cord, and
tension cord.
connect the ma-
chine directly into
the outlet.
You do not use the
Speak to a person
machine for a long
of an approved
time.
service center.
There is remaining
1. Disconnect the
friction in compo-
water supply.
nents. You can
2. Turn the ma-
hear a hum.
chine on for 2
or 3 seconds.
3. Repeat the
above step for
several times.
The water supply
Turn the water
is off.
supply on.
The garden hose is
Make sure that the
blocked.
garden hose is free
from blockage.
120V~ 60 Hz, 13 Amps
2000 PSI
1.1 GPM
104 °F (40 °C)
2200 C.U.
30.6 lbs. (13.9 kg)
Double-insulated construc-
tion.