Operation of the digital controller, see fold-out page IV, Fig. [20].
Button Description
Start/Stop button
Starts and stops the water flow at the saved water temperature and flow rate.
Pause button
Interrupts the water flow. Pressing the button again within 30 seconds, the operation
continues with the last selected settings.
Temperature buttons
Starts the water flow and decreses or increases the water temperature.
Display when maximum temperature is reached (+).
Display when minimum temperature is reached (-).
Volume control
Turning clockwise starts the functional unit and increases the flow rate until maximum.
Turning anti-clockwise reduces the flow rate until minimum.
Memory function
When the water is running the current settings can be saved by pressing and holding
the button.
Cleaning service mode
If no water is flowing, pressing and holding both buttons simultaneously activates
cleaning service mode.
In the cleaning service mode the outlet is closed and without function for 2 minutes.
Abort the cleaning service mode within two minutes by simultaneously pressing and
holding both buttons.
Different functions (F1 to F5) can be set or activated via the digital controller.
Start of the function menu only when no water is flowing.
Function F1 - Automatic filling, see fold-out page IV, Fig. [20].
Button Description
Start the function menu
- Select the function by simultaneously pressing and holding the - / + buttons.
• Start function F1 - Automatic filling
=> Confirm by simultaneously pressing the - / + buttons.
- Stop the water flow/timer by turning the ring anti-clockwise.
- Continue the water flow/timer by turning the ring clockwise.
- Again stop the water flow/timer by turning the ring anti-clockwise.
- After 30 minutes (max. running time) the water flow stops automatically.
- Pressing the - / + buttons saves the quantity/duration and exits the menu. Abort after
3 minutes without triggering (only when no water is flowing).
Abort the function menu by pressing and holding Start/Stop.
Function F2 - Setting mode (adaption to the local conditions), see f old-out page IV, Figs. [20] and [21].
Button Description
Start the function menu
- Select the function by simultaneously pressing and holding the - / + buttons.
- F2 Function select by turning the ring
• Start F2 - Setting mode
=> Confirm by simultaneously pressing the - / + buttons.
Risk of scalding, the outlet temperature could exceed 108 °F!
- Turn ring and set minimum flow rate.
=>
Confirm the setting by simultaneously pressing the - / + buttons.
- Turn ring and set maximum flow rate.
=>
Confirm the setting by simultaneously pressing the - / + buttons.
- Turn ring, measure water outlet temperature and set at 73 °F.
=>
Confirm the setting 73 °F by simultaneously pressing the - / + buttons.
- Turn ring, measure water outlet temperature and set at 108 °F.
Confirm the setting 108 °F by simultaneously pressing the - / + buttons.
=>
Abort the function menu by pressing and holding Start/Stop button or after 3 minutes
without triggering.
Please pass these instructions on to the end user of the fitting.
The right to make technical modifications is reserved.
English
Visualization
The temperature is represented by the illuminated ring.
[from blue to red].
The temperature is represented by the illuminated ring
Illuminated ring flashes red 3x.
Illuminated ring flashes blue 3x.
Water flow is interrupted briefly and the illuminated ring
flashes green 3x
Illuminated ring flashes violet 3x.
Illuminated ring flashes violet 1x when actuated.
Illuminated ring flashes violet 3x.
Visualization
Illuminated ring flashes red 1x.
Illuminated ring flashes green 1x and timer starts.
Water flow/timer stops.
Water flow/timer continues.
Water flow/timer stops.
Water flow stops.
Illuminated ring flashes green 3x.
Illuminated ring flashes violet 1x.
Visualization
Illuminated ring flashes 1x red.
Illuminated ring flashes 2x red.
Illuminated ring flashes green 1x and water flow starts.
Illuminated ring flashes green 1x.
Illuminated ring flashes green 1x.
Illuminated ring flashes green 1x.
Illuminated ring flashes green 3x.
Illuminated ring flashes violet 1x.